DOI 10.1016/j.resuscitation.2026.111144
Tactile stimulation and newborn heart rate responses in the delivery room: an observational video study.
Аннотация
AIMS: Newborn resuscitation guidelines recommend stimulation as a first step in non-breathing newborns to facilitate spontaneous breathing. We aimed to evaluate the extent of stimulation in the delivery room, heart rate (HR) responses to stimulation, and association between bradycardia (HR <100 beats per minute (bpm) ≥10 s) in the first minute after birth and the need for positive pressure ventilation (PPV) versus stimulation alone.
METHOD: A prospective observational study conducted at tertiary level Stavanger University Hospital, Norway, September 2022-July 2024 including newborns with gestational age ≥34 weeks. Stimulation was registered from thermal videos in the delivery room and visible light cameras over resuscitaires. HR was obtained using dry-electrode ECG.
RESULTS
449 included newborns had thermal videos ± visible light video and HR data. 70/449 (16%) newborns did not receive any resuscitative interventions, 345/449 (77%) received stimulation alone, 14/449 (3.1%) received continuous positive airway pressure, and 20/449 (4.4%) received PPV. We observed a HR increase of median 7 bpm among newborns with HR <140 bpm at start stimulation (p < 0.001). Newborns with bradycardia in the first minute after birth had four-fold likelihood of requiring PPV versus tactile stimulation alone (OR 4.81 95% CI 1.39-15.3, p = 0.009).
CONCLUSION
Tactile stimulation is widely applied during neonatal transition. We observed an increase in HR in relation to tactile stimulation, especially among newborns with HR <140 bpm at start stimulation. Newborns with bradycardia (HR <100 bpm ≥10 s) in the first minute after birth had a four-fold likelihood of requiring PPV versus tactile stimulation alone.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.