Control of methicillin-resistant Staphylococcus aureus in a pediatric burn unit.

Sheridan R L, Weber J, Benjamin J, Pasternack M S, Tompkins R G

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Control of methicillin-resistant Staphylococcus aureus (MRSA) is particularly difficult in burn units, which are often cited as sources of hospital-wide MRSA outbreaks. We developed a successful MRSA control program and document here its apparent effectiveness in controlling MRSA transmission in a pediatric burn unit.

METHODS

An MRSA control program that included surveillance culturing, clinician feedback, flexible, site-specific isolation, and a list of known carriers was consistently applied in a pediatric burn unit through a 7-year period. Microbiology reports of MRSA isolates from patients and environmental surfaces and records of all patients from whom MRSA was isolated were reviewed.

RESULTS

During calendar years 1985 through 1991, a total of 991 acutely burned children were admitted to the Boston unit of the Shriners Burns Institute. Forty MRSA cases (4%) were identified. One patient both had MRSA at admission and met our criteria for nosocomial MRSA. Of the remaining 39 patients, 11 had MRSA at admission and 28 had nosocomial MRSA. There were 17 wound infections, two cases of pneumonia, and two bloodstream infections. No deaths were attributed to MRSA sepsis.

CONCLUSION

An MRSA control program including surveillance culturing, clinician feedback, flexible, site-specific isolation, and a list of known carriers is associated with a low rate of nosocomial MRSA in a pediatric burn unit.

Для цитирования: Sheridan R L, Weber J, Benjamin J, Pasternack M S, Tompkins R G. Control of methicillin-resistant Staphylococcus aureus in a pediatric burn unit.. American journal of infection control. 1994. DOI: 10.1016/0196-6553(94)90032-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.