MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jmig.2015.02.007

Медицинская библиотека · Journal of minimally invasive gynecology · 2015

Laparoscopic hysterotomy for a failed termination of pregnancy: a first case report with demonstration of a new surgical technique.

Baekelandt Jan, Bosteels Jan

СтатьяVideo-Audio MediaПеревод в очереди

Аннотация

STUDY

OBJECTIVE

To show a new technique of hysterotomy via laparoscopy for a failed termination of pregnancy as an alternative for a hysterotomy via laparotomy.

DESIGN

Step-by-step explanation of the technique using parts of the original video of the procedure (Canadian Task Force classification III).

SETTING

A 39-year-old woman, para 1 gravida 2, was diagnosed with a trisomy 21 pregnancy at 18 weeks' gestation. After 7 days of failed medical and mechanical induction, including misoprostol per vaginam, intravenous sulprostone , intravenous oxytocin, a transcervical Foley catheter, and a transcervical Bakri balloon (Cooke Medical, Bloomington, IN), the decision was made to perform a laparoscopic hysterotomy.

INTERVENTIONS: A laparoscopic hysterotomy was performed with extraction of the fetus and placenta in an endobag. The uterus was sutured using a double layer of 2 continuous Vicryl 1 sutures (Ethicon, Cincinnati, OH). The umbilical incision was enlarged to 2.5 cm to extract the endobags. The procedure was performed using only standard reusable laparoscopic equipment.

FOLLOW-UP: The patient's postoperative recovery was uneventful. On the postoperative ultrasound, we suspected that a small piece of placental tissue had been left in the uterine cavity. A hysteroscopy confirmed this and showed a normal uterine cavity. The small placental fragment regressed spontaneously on the follow-up ultrasounds. A 2-year follow-up of the patient has shown no minor or major complications. The patient has used contraception since the procedure because she has no further desire for childbearing.

CONCLUSION

This new technique can help surgeons avoid a laparotomy when a hysterotomy for a failed midtrimester termination of pregnancy is required. The risk of uterine rupture in a next pregnancy needs to be taken into account. This frugally innovative technique may potentially be performed in a low-resource setting because only standard reusable laparoscopic equipment was used.

Для цитирования: Baekelandt Jan, Bosteels Jan. Laparoscopic hysterotomy for a failed termination of pregnancy: a first case report with demonstration of a new surgical technique.. Journal of minimally invasive gynecology. 2015. DOI: 10.1016/j.jmig.2015.02.007.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.