DOI 10.1080/09593985.2018.1443358

Медицинская библиотека · Physiotherapy theory and practice · 2018

Reliability of two-point discrimination test in carpal tunnel syndrome patients.

Wolny Tomasz, Linek Paweł

Оценочное исследованиеСтатьяПеревод в очереди

Аннотация

OBJECTIVES

To evaluate the reliability (intra and inter) of two-point discrimination (2PD) test in carpal tunnel syndrome (CTS) patients.

PARTICIPANTS

Eighty-six adults with unilateral right hand CTS.

METHODS

Two examiners performed measurements of 2PD sensation (using Dellon discriminator) on the first three fingers on both hands. The first examiner performed three series of measurements at 1-minute intervals. After 7 days, measurements were repeated by the same examiner (intra-rater). For inter-rater reliability, the examination (by second examiner) was also repeated after 7 days.

RESULTS

For the first measurement, inter-rater reliability (ICC2,1) at the affected site ranged from 0.96 to 0.97; values at the non-affected site ranged from 0.79 to 0.89. Analysis of the averages of two measurements (ICC2,2) yielded values at the affected site of 0.98; values at the non-affected site ranged from 0.92 to 0.94. The average of two measurements reduces the smallest detectable difference (SDD) value < 1 mm in all cases. Intra-rater reliability was at least good for all tested fingers for the first measurement, but to record SDD < 1 mm it is necessary to use an average of the first two measurements.

CONCLUSIONS

The execution of two repeated measurements provides adequate reliability in measurements of 2PD test in CTS patients. For clinical trials, we recommend using at least the average of two measurements of 2PD, which reduce SDD (below 1 mm). This may be particularly important in assessing the effectiveness of therapy.

Для цитирования: Wolny Tomasz, Linek Paweł. Reliability of two-point discrimination test in carpal tunnel syndrome patients.. Physiotherapy theory and practice. 2018. DOI: 10.1080/09593985.2018.1443358.