MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/ajo.12828

Медицинская библиотека · The Australian & New Zealand journal of obstetrics & gynaecology · 2018

Foley catheter silicone versus latex for term outpatient induction of labour: A randomised trial.

McGee Therese M, Gidaszewski Beata, Khajehei Marjan, Tse Toni, Gibbs Emma

Сравнительное исследованиеСтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Both silicone and latex single-balloon Foley catheters are available for cervical ripening but no literature exists to compare them. Local experience suggested more frequent insertion-related accidental rupture of the membranes (acROM) with silicone.

AIMS: To compare the performance of silicone versus latex catheters with respect to acROM and other outcomes.

MATERIALS AND

METHODS

Women undergoing outpatient Foley catheter cervical ripening were randomised to a silicone or latex catheter. Data were collected on the primary outcome, acROM, and secondary outcomes including catheter insertion failure, unplanned hospital admission and patient-reported discomfort, together with intrapartum fever and antibiotics for suspected chorioamnionitis along with general obstetric and neonatal outcomes.

RESULTS

Among 534 recruited women, acROM was significantly more common with a silicone compared to a latex catheter at 7.2% (19/265) versus 1.5% (4/269) (relative risk (RR) 4.8; 95% CI 1.7-14.0). Insertion failure was significantly less common with silicone than latex at 2.6% (7/265) versus 9.3% (25/269) (RR 0.3; 95% CI 0.1-0.6). However, when the alternative catheter was subsequently tried, the final failure rates were 1.9% silicone (5/265) versus 2.6% latex (7/269). Insertion-related hospital admission was higher with silicone at 9.4% (25/265) than latex at 4.8% (13/269) (RR 2.1; 95% CI 1.1-4.1). All other obstetric outcomes were similar between the groups.

CONCLUSION

When used for cervical ripening, a silicone Foley catheter is associated with a higher rate of acROM than a latex catheter but a lower rate of insertion failure. It may, therefore, be reasonable to attempt insertion with a latex catheter initially and manage insertion failures with a silicone catheter.

Для цитирования: McGee Therese M, Gidaszewski Beata, Khajehei Marjan, Tse Toni, Gibbs Emma. Foley catheter silicone versus latex for term outpatient induction of labour: A randomised trial.. The Australian & New Zealand journal of obstetrics & gynaecology. 2018. DOI: 10.1111/ajo.12828.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.