OBJECTIVE

Intraoperative mapping of the nervous system is used to identify "eloquent" cortical areas. In this technical report, we describe a novel way of mapping the somatosensory cortex so that injury to those critical pathways can be avoided.

METHODS

An 8-year-old female with drug resistant epilepsy presented for resection of a right posterior parietal focal cortical dysplasia. Left median nerve stimulation was used to record somatosensory evoked potentials (SEPs) directly from the somatosensory cortex with a strip electrode. A handheld monopolar electrode was also used to record both the median and tibial SEP. Total intravenous anesthesia with propofol and remifentanil was used.

RESULTS

SEP recordings were obtained from a 4-contact strip electrode placed across the central sulcus. A phase reversal was identified and the most likely post central gyrus was noted. With the strip electrode left in place, a monopolar handheld electrode was used to record the median nerve SEPs from different locations on the postcentral gyrus. The tibial nerve was also stimulated to record where the highest amplitude tibial nerve SEP was present. This map was used delineate functionally "eloquent" areas to avoid during surgery. During resection, the median nerve SEP was recorded from the strip electrode continuously. No significant change in the SEP was noted, and the patient awoke without any sensory deficits.

CONCLUSIONS

Sensory mapping of the cortex is possible with a handheld monopolar electrode. This technique is easy to perform and can help reduce neurological morbidity.

Для цитирования: Johnson Holly, Vestal Matthew L, Husain Aatif M. A Novel Technique for Intraoperative Mapping of the Somatosensory Cortex.. World neurosurgery. 2024. DOI: 10.1016/j.wneu.2024.05.118.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.