Surgical treatment of facial fracture by using unsintered hydroxyapatite particles/poly l-lactide composite device (OSTEOTRANS MX(®)): a clinical study on 17 cases.

Hayashi Minoru, Muramatsu Hideyuki, Sato Masahide, Tomizuka Yosuke, Inoue Mayuko, Yoshimoto Shinya

СтатьяПеревод в очереди

Аннотация

BACKGROUND

In Japan we currently use absorption properties for facial fractures. OSTEOTRANS MX(®) (Takiron co., ltd, Japan) is an absorption device, which is called Super FIXSORB MX(®) in Japan. This absorbable osteosynthetic device constitutes unsintered hydroxyapatite particles/poly l-lactide (u-HA/PLLA) composites. This study focuses on reporting clinical cases of using OSTEOTRANS MX(®).

MATERIALS AND

METHODS

Seventeen patients (16 men and 1 woman) aged 10-80 years (mean: 39.9 years, SD: ±20.7) with 86 fracture sites were treated. In all cases we used 1.0 mm plates and 5 mm or 7 mm screws. The postoperative observation period was 6-60 months (mean: 21.8 months, SD: ±14.5).

RESULTS

The fracture site recovered in all cases. Complications included one bone excess on the forehead and one foreign-body reaction on the frontozygomatic suture, but the fracture sites were recovered and had no problems. In the case with the longest observation time 60 months, the plate was almost fully absorbed. However, in other cases the plate was not fully absorbed because of a shorter observation time.

CONCLUSION

OSTEOTRANS MX(®) is a useful device because of its suitable intensity, thinness, radiopaque, and few complications. A longer observation time is required for a plate to be absorbed completely.

Для цитирования: Hayashi Minoru, Muramatsu Hideyuki, Sato Masahide, Tomizuka Yosuke, Inoue Mayuko, Yoshimoto Shinya. Surgical treatment of facial fracture by using unsintered hydroxyapatite particles/poly l-lactide composite device (OSTEOTRANS MX(®)): a clinical study on 17 cases.. Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery. 2013. DOI: 10.1016/j.jcms.2013.01.026.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.