MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1371/journal.pone.0219777

Медицинская библиотека · PloS one · 2019

A controlled-release oral opioid supports S. aureus survival in injection drug preparation equipment and may increase bacteremia and endocarditis risk.

Kasper Katherine J, Manoharan Iswarya, Hallam Brian, Coleman Charlotte E, Koivu Sharon L, Weir Matthew A, McCormick John K, Silverman Michael S

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Injection drug use-associated endocarditis (IDUaIE) incidence in Ontario has recently been associated with hydromorphone prescribing rates. Staphylococcus aureus causes the majority of cases of IDUaIE in Ontario and across North America. Hydromorphone controlled-release (Hydromorphone-CR) requires a complex technique for injection and therefore provides multiple opportunities for contamination. Hydromorphone-CR contains several excipients, which could enhance staphylococcal survival and increase risk of contaminating the injectate.

METHODS

Used injection drug preparation equipment (cookers/filters) was collected from persons who inject drugs (PWID), rinsed with water, and plated on Mannitol salt agar. Bacterial isolates from bacteremic PWID were used to assess the survival of S. aureus and Streptococcus pyogenes on cookers/filters with Hydromorphone-CR, hydromorphone immediate-release (Hydromorphone-IR) or oxycodone controlled-release (Oxycodone-CR). The solutions spiked with S. aureus were heated and the remaining viable bacteria enumerated.

RESULTS

S. aureus was detected in 12/87 (14%, 95%CI 8-23%) cookers/filters samples used for injection of Hydromorphone-CR. Hydromorphone-CR was the only opioid associated with greater survival of methicillin-sensitive S. aureus (MSSA) and methicillin-resistant S. aureus (MRSA) on cookers/filters when compared to sterile water vehicle control. There was a ~2 log reduction in the number of S. aureus that survived when cookers/filters were heated.

CONCLUSION

14% of all cookers/filters used in the preparation of Hydromorphone-CR were contaminated with S. aureus. Hydromorphone-CR prolongs the survival of MRSA and MSSA in cookers/filters. Heating cookers/filters may be a harm-reduction strategy.

Для цитирования: Kasper Katherine J, Manoharan Iswarya, Hallam Brian, Coleman Charlotte E, Koivu Sharon L, Weir Matthew A, McCormick John K, Silverman Michael S. A controlled-release oral opioid supports S. aureus survival in injection drug preparation equipment and may increase bacteremia and endocarditis risk.. PloS one. 2019. DOI: 10.1371/journal.pone.0219777.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.