MedElevator Войти в исследования
← Поиск публикаций

DOI 10.5603/fm.a2018.0012

Медицинская библиотека · Folia morphologica · 2018

Sonography in the instability of the long head of the biceps tendon confronted with histopathologic and arthroscopic findings.

Zabrzyński J, Paczesny Ł, Zabrzyńska A, Grzanka D, Łapaj Ł

Клиническое исследованиеСтатьяПеревод в очереди

Аннотация

BACKGROUND

Disorders of the long head of the biceps (LHB) tendon are a common source of shoulder pain and disability. This tendon can be well visualised using ultrasonography; however, little is known if such examination allows clinicians to predict pathological changes of the tendon structure. In the study described below, we compare preoperative sonographic findings with the data from shoulder arthroscopy and microscopic examination of the excised tendon fragments in 19 consecutive patients with LHB tendinopathy and clinical suspicion of its instability.

MATERIALS AND

METHODS

Preoperative ultrasonographic (US) inspection assessed several features of the tendon, whereas its stability was verified arthroscopically. In all cases, tenodesis or tenotomy procedures were performed and excised tendon fragments were harvested for microscopic examination based on the semiquantitative Bonar score.

RESULTS

The most common US findings were hypoechoic areas, tendon thickening, an increased power Doppler signal and mechanical instability. Just as shoulder arthroscopy confirmed all mechanical instability cases detected in US, microscopic assessment revealed advanced degeneration in all samples.

CONCLUSIONS

Our study indicates that US is a useful tool in identifying cases of advanced instability and LHB tendinopathy, whereas biceps tendon instability is a biomechanically complex, gradually progressing phenomenon, frequently associated with additional shoulder lesions.

Для цитирования: Zabrzyński J, Paczesny Ł, Zabrzyńska A, Grzanka D, Łapaj Ł. Sonography in the instability of the long head of the biceps tendon confronted with histopathologic and arthroscopic findings.. Folia morphologica. 2018. DOI: 10.5603/fm.a2018.0012.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.