Best practices in mitigating the risk of biotin interference with laboratory testing.

СтатьяОбзорНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Bowen Raffick, Benavides Raul, Colón-Franco Jessica M, Katzman Brooke M, Muthukumar Alagarraju, Sadrzadeh Hossein, Straseski Joely, Klause Ursula, Tran Nam

Аннотация

Dietary biotin intake does not typically result in blood biotin concentrations that exceed interference thresholds for in vitro diagnostic tests. However, recent trends of high-dose biotin supplements and clinical trials of very high biotin doses for patients with multiple sclerosis have increased concerns about biotin interference with immunoassays. Estimates of the prevalence of high biotin intake vary, and patients may be unaware that they are taking biotin. Since 2016, 92 cases of suspected biotin interference have been reported to the US Food and Drug Administration. Immunoassays at greatest risk from biotin interference include thyroid and reproductive hormones, cardiac, and immunosuppressive drug tests. Several case studies have highlighted the challenge of biotin interference with thyroid hormone assays and the potential misdiagnosis of Graves' disease. Biotin interference should be suspected when immunoassay test results are inconsistent with clinical information; a clinically relevant biotin interference happens when the blood biotin concentration is high and the assay is sensitive to biotin. We propose a best practice workflow for laboratory scientists to evaluate discrepant immunoassay results, comprising: (1) serial dilution; (2) retesting after biotin clearance and/or repeat testing on an alternate platform; and (3) confirmation of the presence of biotin using depletion protocols or direct measurement of biotin concentrations. Efforts to increase awareness and avoid patient misdiagnosis should focus on improving guidance from manufacturers and educating patients, healthcare professionals, and laboratory staff. Best practice guidance for laboratory staff and healthcare professionals would also provide much-needed information on the prevention, detection, and management of biotin interference.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты