MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/1098612x251410842

Медицинская библиотека · Journal of feline medicine and surgery · 2025

Comparative cadaveric study of needle and conventional arthroscopy techniques of the feline stifle joint.

Koecher-Vodnarek Chiara Anna, Helm Julia, Schnabl-Feichter Eva

СтатьяСравнительное исследованиеПеревод в очереди

Аннотация

ObjectivesArthroscopy is a well-established diagnostic and therapeutic method for canine stifle pathology; however, its use in cats remains under-reported. This study aimed to evaluate and compare the efficacy and safety of conventional arthroscopy (CA) and needle arthroscopy (NA) in feline stifles.MethodsPaired stifles from 20 feline cadavers without clinical or radiographic stifle pathology were randomly assigned to two equal groups: CA (1.9 mm, 30°) and NA (1.9 mm, 0°). Arthroscopy was performed by a board-certified surgeon using a three-portal method and predefined evaluation sequence, ending with medial meniscus assessment. In 10 randomly selected stifles from each group, an extra-articular distractor was applied before medial meniscus evaluation. Procedure duration, visualisation quality, surgical difficulty and cartilage lesions were recorded. Periarticular and iatrogenic articular cartilage injuries (IACIs) were assessed via dissection and India ink staining.ResultsNA yielded a lower mean surgical difficulty score, shorter mean arthroscopy duration and higher rate of complete medial meniscus visualisation than CA. No significant differences were found in absolute IACI (CA with distraction [CA-D]: 4.4 ± 2.8 mm2; CA without distraction [CA-nD]: 5.4 ± 2.4 mm2; NA with distraction [NA-D]: 3.9 ± 2.0 mm2; NA without distraction [NA-nD] 3.6 ± 2.4 mm2) or in percentage surface area affected (CA-D: 1.0 ± 0.6%; CA-nD: 1.3 ± 0.6%; NA-D 0.9 ± 0.4%; NA-nD 0.9 ± 0.6%).Conclusions and relevanceStifle arthroscopy was feasible using both conventional and needle arthroscopes in feline cadavers without stifle pathology and may be considered a minimally invasive tool for diagnosing feline stifle disease. NA in smaller patients may offer advantages over CA in terms of feasibility and procedure duration. Although not statistically significant, NA tended to result in fewer IACIs. IACIs per joint were comparable to values reported in dogs.

Для цитирования: Koecher-Vodnarek Chiara Anna, Helm Julia, Schnabl-Feichter Eva. Comparative cadaveric study of needle and conventional arthroscopy techniques of the feline stifle joint.. Journal of feline medicine and surgery. 2025. DOI: 10.1177/1098612x251410842.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.