m+Medelevator.RU
← Поиск публикаций
[Zhonghua yan ke za zhi] Chinese journal of ophthalmology · 2011

[Three-dimensionally preformed titanium mesh plates for posttraumatic complex orbital bone fracture reconstruction].

Аннотация на английскомСтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Bi Xiao-ping, Fan Xian-qun, Shi Wo-dong, Zhou Hui-fang, Lin Ming, Li Zheng-kang

Аннотация

OBJECTIVE: To evaluate the outcomes of the clinical application of three-dimensionally preformed titanium mesh plates for posttraumatic complex orbital bone fracture reconstruction.

METHODS: Thirteen patients (13 eyes) manifested with complex orbital fractures (including orbital-zygomatic-maxillary bone fracture in 6 patients, nasal-orbital-ethmoid bone fracture in 5 patients and complex multiple periorbital bone fracture in other 2 patients) underwent the reconstructive surgery by using three-dimensionally preformed titanium mesh plates. Eight cases underwent high density porous polyethylene implantation simultaneously. Evaluation of enophthalmos, eyeball movement, and orbit CT scan were taken pre- and post-operatively.

RESULTS: The average enophthalmos was (3.9 ± 1.7) mm and the position of the affected eyeball was (3.1 ± 2.6) mm bellow the contralateral side preoperatively. Twelve patients suffered from eyeball movement restriction, including grade I in 4 cases, grade II in 7 cases and grade III in 2 cases. During the 3 to 6 months post operative follow-up, enophthalmos was completely corrected in 10 patients while the other 3 patients had residual 1.0 mm enophthalmos. The affected eyeballs were repositioned in 8 cases and 3 cases had residual 1 mm lower position and 2 cases with a 1 mm higher positioned eyeball. Eye movement was not restricted in 8 patients, whereas 3 patients had grade I movement restriction and 2 patients had grade II movement restriction. There were no rejection, infection and other complications during follow-up.

CONCLUSIONS: Three-dimensionally preformed titanium mesh plates can be used to reconstruct posttraumatic complex orbital bone fractures in order to improve the orbital volume and to correct enophthalmos effectively.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты