DOI 10.1111/jpc.15978

Медицинская библиотека · Journal of paediatrics and child health · 2022

Button battery taping prevents oesophageal injury.

Wolter Nikolaus E, Wolter Jennifer K, James Adrian L, Ostrow Olivia, McKinnon Nicole K, Everett Tobias, Papsin Blake C, Propst Evan J

СтатьяПеревод в очереди

Аннотация

AIM: Most button battery (BB) ingestions in children are unwitnessed leading to prolonged exposures and severe complications. One third of ingestions occur from free BB, that are stored or awaiting disposal. Recommendations have been made to cover the terminals of discarded BB with adhesive tape; however, it is unclear if this practice prevents injury. Our aim was to determine if tape could prevent oesophageal injury in a cadaveric porcine model.

METHODS

Electrical, masking, packing and duct tape were compared. One BB was left untaped. Taped BBs were placed in a cadaveric porcine oesophagus controlled for temperature and humidification. Specimens were assessed at 0, 0.5, and hourly for 6 h by visual inspection, temperature and pH. BB voltage was measured before and after testing. All tests were repeated in triplicate.

RESULTS

Oesophageal specimens demonstrated burn prevention in the packing and duct tape trials. Burns were seen in 2/3 trials with electrical tape and 3/3 trials with masking tape. pH remained neutral throughout the study for all packing and duct tape specimens. pH remained neutral initially for masking tape but increased rapidly to 12 by 2 h. There was no change in battery voltage for the packing tape and duct tape trials. There was a 16.3% reduction in voltage for masking tape which was similar to controls.

CONCLUSIONS

Taping BB with packing tape and duct tape prevented oesophageal burns. This may provide a novel method of burn prevention for loose BB intended for disposal.

Для цитирования: Wolter Nikolaus E, Wolter Jennifer K, James Adrian L, Ostrow Olivia, McKinnon Nicole K, Everett Tobias, Papsin Blake C, Propst Evan J. Button battery taping prevents oesophageal injury.. Journal of paediatrics and child health. 2022. DOI: 10.1111/jpc.15978.