m+Medelevator.RU
← Поиск публикаций
Journal of AAPOS : the official publication of the American Association for Pediatric Ophthalmology and Strabismus · 2022

Intraorbital self-inflating hydrogel expander implantation with a modified technique in congenital microphthalmia.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Wu Pengsen, Lin Bingying, Sun Tianying, Li Xingyi, Meng Jie, Zhang Fan, Huang Danping

Аннотация

PURPOSE: To investigate the long-term outcomes of intraorbital self-inflating hydrogel expander implantation with optic nerve transection in children with congenital microphthalmia.

METHODS: The medical records of unilaterally blind microphthalmic pediatric patients undergoing intraconal hydrogel expander implantation with optic nerve transection were reviewed retrospectively. For each patient, the microphthalmic eye was preserved. The orbital volume and globe volume were measured and analyzed based on computed tomography scans taken preoperatively and 36 months postoperatively. The palpebral length was measured between the medial and lateral canthus at every follow-up. Surgical complications were also recorded.

RESULTS: Twelve patients were included (median age, 44.25 ± 17.5 months). At 36 months postoperatively, the microphthalmic and contralateral orbital volumes increased by 3.07 ± 0.77 ml and 2.03 ± 0.67 ml, respectively. The mean microphthalmic/contralateral ratio (MCR) of the orbital volume increased significantly from 76.60% ± 5.46% to 83.81% ± 5.41% (P < 0.001). The microphthalmic palpebral length increased by 6.17 ± 1.85 mm, whereas the contralateral palpebral length increased by 2.67 ± 1.44 mm. Significant changes were observed in the palpebral length MCR (68.00% ± 4.83% vs 85.07% ± 3.87%; P < 0.001). There was no significant change in the microphthalmic globe volume at 36 months postoperatively (P = 0.215). For the fellow eye, the globe volume increased significantly by 0.53 ± 0.34 ml (P < 0.001). During the follow-up period, 2 patients developed a sunken prosthesis. One patient had difficulty opening the eye after wearing the conformer. There were no cases of expander rejection or extrusion.

CONCLUSIONS: In this small cohort of patients with congenital microphthalmia, intraorbital self-expanding hydrogel expander implantation with optic nerve transection led to excellent osseous and eyelid growth throughout the 36-month follow-up period.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты