The Diagnostic Reproducibility of Tomosynthesis for the Correlation between Acromiohumeral Distance and Rotator Cuff Size or Type.

Song Yoonah, Lee Seunghun, Lee Bong Gun, Joo Young Bin, Song Soon-Young

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To correlate the acromiohumeral distance (AHD) using tomosynthesis and rotator cuff (RC) pathology and various anatomical indices and to assess the diagnostic reproducibility of tomosynthesis for the evaluation of subacromial impingement.

MATERIALS AND

METHODS

A retrospective review of 63 patients with clinically suspected subacromial impingement was conducted. Two musculoskeletal radiologists independently measured the following quantitative data: the AHD on plain radiographs and the AHD at three compartments (anterior, middle, and posterior) using tomosynthesis, computed tomography (CT) arthrography, or magnetic resonance (MR) arthrography. To investigate the association between the AHD and RC pathology and various anatomical indices, we reviewed the arthroscopic operation record as the referenced standard.

RESULTS

The size of rotator cuff tear (RCT) in full-thickness tears displayed a significant inverse correlation with the middle and the posterior tomosynthetic AHDs (p < 0.05). The results of an ANOVA revealed that the middle tomosynthetic AHD retained a significant association with the type of RCT (p = 0.042), and the posterior tomosynthetic AHD retained significance for the size of RCT in a full-thickness tear (p = 0.024). The inter-modality correlation exhibited significant agreement especially among the plain radiography, tomosynthesis, and CT or MR arthrography (p < 0.05). The intraobserver and interobserver correlation coefficients (ICCs) displayed excellent agreement (ICC = 0.896-0.983). The humeral head diameter and glenoid height were significantly correlated with patient height and weight.

CONCLUSION

Acromiohumeral distance measurement using tomosynthesis is reproducible compared with other modalities.

Для цитирования: Song Yoonah, Lee Seunghun, Lee Bong Gun, Joo Young Bin, Song Soon-Young. The Diagnostic Reproducibility of Tomosynthesis for the Correlation between Acromiohumeral Distance and Rotator Cuff Size or Type.. Korean journal of radiology. 2018. DOI: 10.3348/kjr.2018.19.3.417.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.