Goetschius John, Hertel Jay, Saliba Susan, Brockmeier Stephen F, Hart Joseph M
Аннотация
OBJECTIVES: To examine the immediate effects of prolonged patellar tendon vibration on quadriceps strength in anterior cruciate ligament reconstructed (ACLR) knees with bone-patellar tendon-bone (BTB) grafts and non-BTB grafts, and healthy control knees.
DESIGN: Pretest-posttest design.
SETTING: Laboratory.
PARTICIPANTS: Young adult participants were stratified into one of three groups: non-BTB graft (n = 25), BTB graft (n = 26), and controls without ACLR (n = 21).
MAIN OUTCOME MEASURES: Maximum voluntary isometric contraction (MVIC) knee extension torque was measured at baseline and following a 20-min vibration intervention applied locally to the patellar tendon.
RESULTS: Our findings suggest there was no difference in the effects of vibration on knee extension torque between the three groups. Knee extension torque significantly increased (effect size = 0.52 [0.18 to 0.81]) from baseline to post-vibration across all three groups (0.30 ± 0.26 Nm/kg, 21.8 ± 20.0%). Both ACLR groups demonstrated significantly lower knee extension torque compared the control group.
CONCLUSIONS: The vibration intervention had a net excitatory effect on quadriceps strength in all three groups and there were no differences in the magnitude of change between the three groups. Vibration could become a useful tool for enhancing quadriceps strength in ACLR and healthy knees.
DESIGN: Pretest-posttest design.
SETTING: Laboratory.
PARTICIPANTS: Young adult participants were stratified into one of three groups: non-BTB graft (n = 25), BTB graft (n = 26), and controls without ACLR (n = 21).
MAIN OUTCOME MEASURES: Maximum voluntary isometric contraction (MVIC) knee extension torque was measured at baseline and following a 20-min vibration intervention applied locally to the patellar tendon.
RESULTS: Our findings suggest there was no difference in the effects of vibration on knee extension torque between the three groups. Knee extension torque significantly increased (effect size = 0.52 [0.18 to 0.81]) from baseline to post-vibration across all three groups (0.30 ± 0.26 Nm/kg, 21.8 ± 20.0%). Both ACLR groups demonstrated significantly lower knee extension torque compared the control group.
CONCLUSIONS: The vibration intervention had a net excitatory effect on quadriceps strength in all three groups and there were no differences in the magnitude of change between the three groups. Vibration could become a useful tool for enhancing quadriceps strength in ACLR and healthy knees.