MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1080/0886022x.2024.2353351

Медицинская библиотека · Renal failure · 2024

Sharp needle reconstructs peripheral outflow for patients with malfunctional arteriovenous fistula.

Xu Yong, Zhu Shu-Yuan, Li Yuan-Ming, Liu Xin-Xin, Zhang Hao, Wang Lu-Fang

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To investigate the feasibility and efficacy of combining ultrasound-guided sharp needle technique with percutaneous transluminal angioplasty (PTA) for treating outflow stenosis or dysfunction in arteriovenous fistula (AVF) among hemodialysis patients.

METHODS

From October 2021 to March 2023, patients with occluded or malfunctional fistula veins not amenable to regularly angioplasty were retrospectively enrolled in the study. They underwent ultrasound-guided sharp needle intervention followed by PTA. Data on the location and length between the two veins, technical success, clinical outcomes, and complications were collected. Patency rates post-angioplasty were calculated through Kaplan-Meier analysis.

RESULTS

A total of 23 patients were included. The mean length of the reconstructed extraluminal segment was 3.18 cm. The sharp needle opening was performed on the basilic vein (60.9%), brachial vein (26.1%), or upper arm cephalic vein (13%) to create outflow channels. Postoperatively, all cases presented with mild subcutaneous hematomas around the tunneling site and minor diffuse bleeding. The immediate patency rate for the internal fistulas was 100%, with 3-month, 6-month, and 12-month patency rates at 91.3%, 78.3%, and 43.5%, respectively.

CONCLUSION

Sharp needle technology merged with PTA presents an effective and secure minimally invasive method for reconstructing the outflow tract, offering a new solution for recanalizing high-pressure or occluded fistulas.

Для цитирования: Xu Yong, Zhu Shu-Yuan, Li Yuan-Ming, Liu Xin-Xin, Zhang Hao, Wang Lu-Fang. Sharp needle reconstructs peripheral outflow for patients with malfunctional arteriovenous fistula.. Renal failure. 2024. DOI: 10.1080/0886022x.2024.2353351.