MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jse.2018.04.014

Медицинская библиотека · Journal of shoulder and elbow surgery · 2018

Clinical measurements for inferior, posterior, and superior glenohumeral joint contracture evaluation in children with brachial plexus birth palsy: intraobserver and interobserver reliability.

Hodgson Felipe, Alabau-Rodriguez Sergi, Barrera-Ochoa Sergi, Gharbaoui Idriss, Knörr Jorge, Soldado Francisco

СтатьяНаблюдательное исследованиеПеревод в очереди

Аннотация

BACKGROUND

Glenohumeral (GH) contractures appear in most patients with incomplete motor recovery as a result of progressive development of periarticular muscle contractures. The objectives of this study were to describe a method to measure the passive range of motion of the glenohumeral joint (GHJ) in patients with brachial plexus birth palsy (BPBP) and to evaluate its intraobserver and interobserver reproducibility.

METHODS

Three orthopedic surgeons measured the passive GHJ mobility of 25 patients older than 4 years with unilateral BPBP. Measurements were performed twice on both shoulders. They comprised the spinohumeral abduction angle (SHABD), spinohumeral adduction angle (SHADD), GH cross-body adduction (CBADD), and GH internal rotation in abduction (IRABD). Anterior GH contracture was not evaluated.

RESULTS

Passive shoulder measurements obtained from the uninvolved and involved shoulders were as follows: SHABD, 42° and 18°, respectively; SHADD, 14° and -1°, respectively; CBADD, 71° and 41°, respectively; and IRABD, 54° and 37°, respectively. Contracture of the lower portion of the involved GHJ was observed in 18 of 25 patients (72%); the upper portion, in 16 of 25 (64%); and the posterior portion, in 22 of 25 (88%). Interobserver variation (intraclass correlation coefficient) was 0.91 (excellent) for SHABD, 0.63 (good) for SHADD, 0.86 (excellent) for CBADD, and 0.67 (good) for IRABD. Intraobserver variation (intraclass correlation coefficient) was 0.94 (excellent) for SHABD, 0.87 (excellent) for SHADD, 0.92 (excellent) for CBADD, and 0.89 (excellent) for IRABD.

CONCLUSIONS

Clinical measurements of passive GHJ range-of-motion analyzed in this study showed excellent or good intraobserver and interobserver variability. Our study showed that BPBP resulted in a multidirectional GH contracture in most patients. We have described a simple and reliable way to evaluate passive GH motion, providing reliable anatomic landmarks.

Для цитирования: Hodgson Felipe, Alabau-Rodriguez Sergi, Barrera-Ochoa Sergi, Gharbaoui Idriss, Knörr Jorge, Soldado Francisco. Clinical measurements for inferior, posterior, and superior glenohumeral joint contracture evaluation in children with brachial plexus birth palsy: intraobserver and interobserver reliability.. Journal of shoulder and elbow surgery. 2018. DOI: 10.1016/j.jse.2018.04.014.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.