PURPOSE: In this study we report our experiences with the treatment of midfacial fractures and various other indications in regions with low load bearing (eg, dysmorphias) using the biodegradable Osteosynthesis System (SonicWeld Rx by KLS Martin, Tuttlingen, Germany), comprising biomechanical and histological aspects.

PATIENTS AND

METHODS

Seventy-five patients were included in this study. We describe the application of this system for the treatment of fractures of the zygomamaxillary complex, frontal bone impression fractures, surgical treatment of mukocele in the frontal sinus, isolated fractures of the orbital floor, complex midfacial trauma and bone cap fixation, craniosynostoses, and fixation of a distracted bone fragment.

RESULTS

The pin insertion could be finished with a total failure rate of lower than 5%. In 3 patients, soft tissue swellings in regions with less subcutaneous fat were observed 6 to 8 months postoperatively. No fracture dislocations occurred. Scanning electron micrograph of the experimentally acquired connection between the resorbable plate and 2 pins clearly demonstrates a tight and reliable fusion to bone, both at the cortical as well as at the spongy compartment. Conventional histology leads to corresponding findings as scanning electron micrography, and shows a close fusion between all components.

CONCLUSION

This retrospective study shows the general feasibility, sufficient mechanical stability, and efficient intraoperative handling of this angle-stable, ultrasonic-guided resorbable Osteosynthesis System (ResorbX and SonicWeld Rx) for a wide variety of indications in craniomaxillofacial surgery.

Для цитирования: Reichwein Astrid, Schicho Kurt, Moser Doris, Seemann Rudolf, Poeschl Paul, Baumann Arnulf, Ewers Rolf. Clinical experiences with resorbable ultrasonic-guided, angle-stable osteosynthesis in the panfacial region.. Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons. 2009. DOI: 10.1016/j.joms.2008.12.033.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.