MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1682/jrrd.2010.04.0053

Медицинская библиотека · Journal of rehabilitation research and development · 2011

Quantitative evaluations of ankle spasticity and stiffness in neurological disorders using manual spasticity evaluator.

Peng Qiyu, Park Hyung-Soon, Shah Parag, Wilson Nicole, Ren Yupeng, Wu Yi-Ning, Liu Jie, Gaebler-Spira Deborah J, Zhang Li-Qun

СтатьяПоддержка NIH: внешняя программаПоддержка правительства СШАПеревод в очереди

Аннотация

Spasticity and contracture are major sources of disability in people with neurological impairments that have been evaluated using various instruments: the Modified Ashworth Scale, tendon reflex scale, pendulum test, mechanical perturbations, and passive joint range of motion (ROM). These measures generally are either convenient to use in clinics but not quantitative or they are quantitative but difficult to use conveniently in clinics. We have developed a manual spasticity evaluator (MSE) to evaluate spasticity/contracture quantitatively and conveniently, with ankle ROM and stiffness measured at a controlled low velocity and joint resistance and Tardieu catch angle measured at several higher velocities. We found that the Tardieu catch angle was linearly related to the velocity, indicating that increased resistance at higher velocities was felt at further stiffer positions and, thus, that the velocity dependence of spasticity may also be position-dependent. This finding indicates the need to control velocity in spasticity evaluation, which is achieved with the MSE. Quantitative measurements of spasticity, stiffness, and ROM can lead to more accurate characterizations of pathological conditions and outcome evaluations of interventions, potentially contributing to better healthcare services for patients with neurological disorders such as cerebral palsy, spinal cord injury, traumatic brain injury, and stroke.

Для цитирования: Peng Qiyu, Park Hyung-Soon, Shah Parag, Wilson Nicole, Ren Yupeng, Wu Yi-Ning, Liu Jie, Gaebler-Spira Deborah J, Zhang Li-Qun. Quantitative evaluations of ankle spasticity and stiffness in neurological disorders using manual spasticity evaluator.. Journal of rehabilitation research and development. 2011. DOI: 10.1682/jrrd.2010.04.0053.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.