MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/0003-4975(95)00304-4

Медицинская библиотека · The Annals of thoracic surgery · 1995

Aortic valve replacement with allograft/autograft: subcoronary versus intraluminal cylinder or root.

Rubay J E, Raphael D, Sluysmans T, Vanoverschelde J L, Robert A, Schoevaerdts J C, Marchandise B, Dion R A

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

From April 1990 to May 1994, 89 patients (median age, 42 years; range, 10 days to 66 years) underwent aortic valve or root replacement with allografts or autografts. Thirteen patients were less than 18 years old at the time of operation. Indication for aortic valve replacement was aortic stenosis (50 patients, 56%), small stenotic prosthesis (2 patients, 2%), aortic valve endocarditis (19 patients, 21%), isolated aortic regurgitation (17 patients, 19%), and type II truncus arteriosus (1 patient, 1%). The subcoronary implantation was used in 45 patients (group A), and implantation of an intraluminal cylinder (16 patients) or complete root replacement (28 patients) was performed in the remaining 44 patients (group B). The Ross procedure was performed in 22 patients. Intraoperative transesophageal echocardiography was used routinely. Five patients died in the early postoperative period (6%), 2 in group A and 3 in group B. Three other patients required immediate replacement of a failing graft by a mechanical prosthesis (1 in group A and 2 in group B). There has been no late death. All survivors remained in New York Heart Association functional class I and were free of thromboembolic complications. Endocarditis occurred in 2 patients, 1 year after operation. Both were successfully treated medically. Echocardiographic studies were obtained serially in every patient. Four patients, 2 in group A and 2 in group B underwent reoperation because of mild-to-moderate aortic regurgitation (rate of reoperation, 5%). Two valves were repaired and two were replaced by an allograft.(ABSTRACT TRUNCATED AT 250 WORDS)

Для цитирования: Rubay J E, Raphael D, Sluysmans T, Vanoverschelde J L, Robert A, Schoevaerdts J C, Marchandise B, Dion R A. Aortic valve replacement with allograft/autograft: subcoronary versus intraluminal cylinder or root.. The Annals of thoracic surgery. 1995. DOI: 10.1016/0003-4975(95)00304-4.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.