m+Medelevator.RU
← Поиск публикаций
High altitude medicine & biology · 2024

Quality of Cardiopulmonary Resuscitation in Avalanche Victims with a Single Rescuer: A Prospective, Crossover, Manikin Pilot Study.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Tanaka Shota, Nakagawa Koshi, Kanagawa Yosuke, Katsurahara Takashi, Kozakai Kazuki, Tsuhako Ken, Yoshikawa Fumitaka, Gotoh Soh, Osanai Kensuke, Sono Madoka, Inoue Hironori, Sakanashi Shuji, Takahashi Hiroyuki, Tanaka Hideharu

Аннотация

Tanaka, Shota, Koshi Nakagawa, Yosuke Kanagawa, Takashi Katsurahara, Kazuki Kozakai, Ken Tsuhako, Fumitaka Yoshikawa, Soh Gotoh, Kensuke Osanai, Madoka Sono, Hironori Inoue, Shuji Sakanashi, Hiroyuki Takahashi, and Hideharu Tanaka. Quality of cardiopulmonary resuscitation in avalanche victims with a single rescuer: a prospective, crossover, manikin pilot study. High Alt Med Biol. 25:60-67, 2024. Background: Winter outdoor recreational activities such as off-piste skiing have gained popularity and, as a result, the number of avalanche-related deaths has increased. However, the quality of cardiopulmonary resuscitation (CPR) at avalanche sites remains unclear. Our study compared the quality of CPR performed in a simulated avalanche burial on a snowy mountain with that performed indoors. Methods: Ten prehospital health care providers participated in the crossover pilot study. Various methods, including over-the-head CPR (OTH-CPR) and standard CPR, were used to perform avalanche resuscitation, with five rescue breaths, followed by 30 chest compressions and two breaths. The quality CPR was judged by four variables of chest compression and ventilation. Results: The OTH-CPR performed indoors was better in quality: 5.33% [95% confidence interval (CI) -14.2 to 3.5] higher in adequate compression depth (94.3 ± 10.6% on the snow vs. 99.3 ± 1.1% indoors), 3.4% [95% CI -16.1 to 22.9] higher in adequate compression rate (70.4 ± 38.0% vs. 76.1 ± 35.7%), and 2.3% [95% CI -6.4 to 1.72] higher in adequate recoil (96.9 ± 4.8% vs. 99.2 ± 1.6%) than OTH-CPR on the snow. In terms of ventilation quality, OTH-CPR performed indoors had a 50% higher ventilation score [95% CI -73.0 to -27.0] than OTH-CPR on the snow (1.4 ± 4.3% vs. 45.9 ± 32.6%, Cohen's d = -1.81). Conclusions: Chest compression quality was slightly impaired in the avalanche scenarios on the snow than in indoor settings. Asphyxiation is the main cause of avalanche-related deaths; however, low ventilation quality was observed on snow compared with the indoor setting.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты