MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00247-017-3882-1

Медицинская библиотека · Pediatric radiology · 2017

Analysis of normal and dysplastic glenohumeral morphology at magnetic resonance imaging in children with neonatal brachial plexus palsy.

van de Bunt Fabian, Pearl Michael L, Lee Eric K, Peng Lauren, Didomenico Paul

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Glenoid version and percentage of the humeral head anterior to the scapular line are commonly used 2-D measures to assess deformity of the glenohumeral joint of children with neonatal brachial plexus palsy.

OBJECTIVE

To assess whether glenoid version and percentage of the humeral head anterior to the scapular line would be altered by standardizing the measurements to the orientation of the scapula.

MATERIALS AND

METHODS

Twenty-one bilateral magnetic resonance imaging (MRI) scans were evaluated by four reviewers. Measurements were performed on the axial image slices and again after applying 3-D reformatting.

RESULTS

Three-dimensional reformatting led to intrapatient corrections up to 25° for version and -30% for percentage of the humeral head anterior to the scapular line. The mean difference on the involved side between clinical and anatomical version across all subjects from all reviewers was 2.2° ± 3.9° (range: -4.5° to 11.5°). The mean difference in the percentage of the humeral head anterior to the scapular line after reformatting was -1.8% (range: -15.9% to 5.2%).

CONCLUSION

Measurements can differ greatly for the same child depending on technical factors of image acquisition and presentation in the clinical setting. With this study, we present a clinically accessible protocol to correct for scapular orientation from MRI data of children with neonatal brachial plexus palsy.

Для цитирования: van de Bunt Fabian, Pearl Michael L, Lee Eric K, Peng Lauren, Didomenico Paul. Analysis of normal and dysplastic glenohumeral morphology at magnetic resonance imaging in children with neonatal brachial plexus palsy.. Pediatric radiology. 2017. DOI: 10.1007/s00247-017-3882-1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.