MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/uog.20259

Медицинская библиотека · Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology · 2019

Fetal heart rate variability with hypoxemia in an instrumented sheep model.

Bhide A, Johnson J, Rasanen J, Acharya G

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

OBJECTIVE

To examine the effect of hypoxemia on fetal heart rate (FHR) variability, using an instrumented pregnant sheep model.

METHODS

In this prospective study, 19 pregnant sheep were instrumented under general anesthesia, at a mean gestational age of 127 days. After a 5-day recovery period, hypoxemia was induced by attaching the mother to a rebreathing circuit. Hypoxemia was sustained for 120 min, following which it was reversed until maternal and fetal partial pressure of oxygen (pO2 ) returned to baseline. FHR recordings at baseline, after 30 and 120 min of hypoxemia and at recovery were analyzed to calculate short-term variation (STV) in 16 epochs of 3.75 s, every minute. Phase-rectified signal averaging (window length (L) = 10, time (T) = 2 and scale (S) = 2) was used to calculate FHR acceleration (AC) and deceleration (DC) capacities.

RESULTS

At baseline, mean ± SD fetal pO2 was 2.90 ± 0.38 kPa. Acute hypoxemia was associated with a significant reduction in mean pO2 at 30 (1.62 ± 0.37 kPa) and 120 (1.51 ± 0.16 kPa) min. Mean ± SD fetal pO2 at recovery was 2.86 ± 0.32 kPa. At baseline, median STV, AC and DC were 1.307 (interquartile range (IQR), 0.515-2.508) ms, 1.295 (IQR, 0.990-2.685) beats per minute (bpm) and 1.197 (IQR, 0.850-1.836) bpm, respectively. At 30 min of hypoxemia, the values were 1.323 (IQR, 0.753-2.744) ms, 1.696 (IQR, 1.310-3.013) bpm and 1.584 (IQR, 1.217-4.132) bpm, respectively. At 120 min of hypoxemia, they were 1.760 (IQR, 0.928-4.656) ms, 3.098 (IQR, 1.530-5.163) bpm and 3.054 (IQR, 1.508-4.522) bpm, respectively. At recovery, they changed to 0.962 (IQR, 0.703-1.154) ms, 1.228 (IQR, 1.071-2.234) bpm and 1.086 (IQR, 0.873-1.568) bpm, respectively. Hypoxemia for 30 and 120 min was associated with a significant increase in DC compared to baseline (P = 0.014 and 0.017, respectively). The changes in STV and AC were not significant.

CONCLUSION

Acute hypoxemia is associated with a significant increase in the DC of FHR in a fetal sheep model. Copyright © 2019 ISUOG. Published by John Wiley & Sons Ltd.

Для цитирования: Bhide A, Johnson J, Rasanen J, Acharya G. Fetal heart rate variability with hypoxemia in an instrumented sheep model.. Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology. 2019. DOI: 10.1002/uog.20259.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.