Influenza associated cardiac arrhythmia- a systematic review.

Alam Md Mashiul, Paul Timir, Aggarwal Abhinav, Zarich Stuart

Систематический обзорСтатьяПеревод в очереди

Аннотация

BACKGROUND

Influenza infection is rarely associated with cardiac conduction disorder. Cardiac arrhythmias due to such an infection have a full spectrum with ventricular arrythmias being the most common.

METHODS

In our systematic review from PubMed, OVID Medline and EMBASE we have identified 23 articles describing arrythmias associated with different influenza infection. Most of them were case reports where ventricular arrhythmias were the most common.

RESULTS

Complete heart block after influenza infection is usually temporary and a permanent pacemaker is rarely needed. There are reports of Influenza associated with arrhythmias in adults, neonates, and even fetuses in pregnant woman. Different mechanisms were described in literatures by which influenza causes arrhythmias such as interleukin 6 & tumor necrosis factor-alpha mediated inflammatory response, sympathetic overactivation, focal myocarditis and cleavage of angiotensin converting enzyme 2 protein which is cardioprotective.

CONCLUSIONS

ACE 2 binder influenza viruses have more prone to be associated with cardiac conduction disorder. Oseltamivir for influenza infection is also associated with bradycardia and can shorten or lengthen QT segment. Influenza vaccination has found to be protective from cardiac arrhythmia.

Для цитирования: Alam Md Mashiul, Paul Timir, Aggarwal Abhinav, Zarich Stuart. Influenza associated cardiac arrhythmia- a systematic review.. The American journal of the medical sciences. 2024. DOI: 10.1016/j.amjms.2024.01.004.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.