DOI 10.1016/j.ogla.2018.06.003
Treatment Outcomes of Mitomycin C-Augmented Trabeculectomy, Sub-Tenon Injection versus Soaked Sponges, after 3 Years of Follow-up: A Randomized Clinical Trial.
Аннотация
PURPOSE: To report the 3-year outcome of trabeculectomy with mitomycin C (MMC)-soaked sponges versus intra-Tenon injection of MMC in eyes with uncontrolled primary open-angle glaucoma.
DESIGN
Randomized clinical trial.
PARTICIPANTS
Eighty-two consecutive patients with uncontrolled primary open-angle glaucoma.
METHODS
Participants were randomized either to intra-Tenon injection of 0.1 ml of 0.01% MMC (TI group) or 0.02% subconjunctival application of MMC-soaked sponges (TS group). Patients were followed up for 3 years after surgery. The data for 73 eyes were included in the final analysis.
MAIN OUTCOME MEASURES: The primary outcome measure was the surgical success, defined as intraocular pressure (IOP) more than 5 mmHg and <21 mmHg, and IOP reduction of 20% or more from baseline, no reoperation for glaucoma, and no loss of light perception vision. Secondary outcome measures were IOP, glaucoma medications, best-corrected visual acuity (VA), bleb morphologic features according to the Indiana Bleb Appearance Grading Scale, complications, and endothelial cell count changes.
RESULTS
The cumulative probability of success at 3-year follow-up was 72.2% in the TI group and 65.1% in the TS group (P = 0.30). Uncontrolled IOP was the most common reason for failure. The mean preoperative IOP was 22.4±4.6 mmHg with an average of 3.1±1.0 medications. At 3 years, final IOP was 15.3±3.7 mmHg in the TI group and 16.4±3.5 mmHg in the TS group (P = 0.55). Mean glaucoma number of medications was 0.9±1.1 and 1.1±1.1 in the TI and TS groups, respectively (P = 0.54). Blebs tended to be more diffuse (P = 0.032), less vascularized (P = 0.013), and more shallow (P = 0.012) after intra-Tenon injection. Visual outcomes and endothelial cell changes were similar in both groups (P = 0.47 and P = 0.94, respectively).
CONCLUSIONS
Although the success rate and IOP reduction were comparable with both techniques, bleb morphologic parameters were more favorable after intra-Tenon injection of 0.1 ml of 0.01% MMC.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.