DOI 10.1016/j.injury.2021.08.011
Single sterile silicon ring technique for utilization of upper limb intravenous regional anesthesia: A prospective study of patients with operated distal radius fractures.
Аннотация
INTRODUCTION
Intravenous regional anesthesia is a well-established method of anesthesia in upper extremity surgery. In this study, we present a modification of the technique using a silicon ring tourniquet in 30 patients undergoing internal fixation for distal radius fractures.
METHODS
A sterile silicone ring wrapped within a stockinette sleeve was applied, and a local anesthetic solution (3 mg/kg lidocaine 0,5%) was injected intravenously. After anesthesia onset, the ring was rolled distally to provide immediate pain and discomfort relief.
RESULTS
The silicone ring achieved adequate exsanguination in all patients. Mean pain VAS score was 2.7 ± 0.9 intraoperatively and 4.3 ± 1.3 during the first hour postoperatively. The onset and termination times of sensory block were 5.8 ± 2.1 and 102 ± 7.8 min, and of motor block 13.8 ± 2.8 and 54.2 ± 4.6 min, accordingly. All patients were satisfied from the procedure.
CONCLUSION
Sterile silicone ring tourniquet application is a simple, safe and effective analgesic and anesthetic technique for the operative treatment of distal radius fractures.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.