Radiology · 2012
CO2 blood oxygen level-dependent MR mapping of cerebrovascular reserve in a clinical population: safety, tolerability, and technical feasibility.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Spano Vincent R, Mandell Daniel M, Poublanc Julien, Sam Kevin, Battisti-Charbonney Anne, Pucci Olivia, Han Jay S, Crawley Adrian P, Fisher Joseph A, Mikulis David J
Аннотация
PURPOSE: To evaluate the safety, tolerability, and technical feasibility of mapping cerebrovascular reactivity (CVR) in a clinical population by using a precise prospectively targeted CO(2) stimulus and blood oxygen level-dependent (BOLD) magnetic resonance (MR) imaging.
MATERIALS AND METHODS: A chart review was performed of all CVR studies from institutional review board-approved projects at a tertiary care hospital between January 1, 2006, and December 1, 2010. Informed consent was obtained. Records were searched for the incidence of adverse events and failed examinations. CVR maps were evaluated for diagnostic quality by two blinded observers and were categorized as good, diagnostic but suboptimal, or nondiagnostic. Outcomes were presented as raw data and descriptive statistics (means ± standard deviations). Intraclass correlation coefficient was used to determine interobserver variability.
RESULTS: Four hundred thirty-four consecutive CVR examinations from 294 patients (51.8% female patients) were studied. Patient age ranged from 9 to 88 years (mean age, 45.9 years ± 20.6). Transient symptoms, such as shortness of breath, headache, and dizziness, were reported in 48 subjects (11.1% of studies) during hypercapnic phases only. There were no neurologic ischemic events, myocardial infarctions, or other major complications. The success rate in generating CVR maps was 83.9% (364 of 434). Of the 70 (16.1%) failed examinations, 25 (35.7%) were due to discomfort; eight (11.4%), to head motion; two (2.9%), to inability to cooperate; seven (10.0%), to technical difficulties with equipment; and 28 (40.0%), to unknown or unspecified conditions. Among the 364 remaining successful examinations, good quality CVR maps were obtained in 340 (93.4%); diagnostic but suboptimal, in 12 (3.3%); and nondiagnostic, in 12 (3.3%).
CONCLUSION: CVR mapping by using a prospectively targeted CO(2) stimulus and BOLD MR imaging is safe, well tolerated, and technically feasible in a clinical patient population.
MATERIALS AND METHODS: A chart review was performed of all CVR studies from institutional review board-approved projects at a tertiary care hospital between January 1, 2006, and December 1, 2010. Informed consent was obtained. Records were searched for the incidence of adverse events and failed examinations. CVR maps were evaluated for diagnostic quality by two blinded observers and were categorized as good, diagnostic but suboptimal, or nondiagnostic. Outcomes were presented as raw data and descriptive statistics (means ± standard deviations). Intraclass correlation coefficient was used to determine interobserver variability.
RESULTS: Four hundred thirty-four consecutive CVR examinations from 294 patients (51.8% female patients) were studied. Patient age ranged from 9 to 88 years (mean age, 45.9 years ± 20.6). Transient symptoms, such as shortness of breath, headache, and dizziness, were reported in 48 subjects (11.1% of studies) during hypercapnic phases only. There were no neurologic ischemic events, myocardial infarctions, or other major complications. The success rate in generating CVR maps was 83.9% (364 of 434). Of the 70 (16.1%) failed examinations, 25 (35.7%) were due to discomfort; eight (11.4%), to head motion; two (2.9%), to inability to cooperate; seven (10.0%), to technical difficulties with equipment; and 28 (40.0%), to unknown or unspecified conditions. Among the 364 remaining successful examinations, good quality CVR maps were obtained in 340 (93.4%); diagnostic but suboptimal, in 12 (3.3%); and nondiagnostic, in 12 (3.3%).
CONCLUSION: CVR mapping by using a prospectively targeted CO(2) stimulus and BOLD MR imaging is safe, well tolerated, and technically feasible in a clinical patient population.