The development and validation of a cerebral ultrasound scoring system for infants with hypoxic-ischaemic encephalopathy.
Аннотация
BACKGROUND
Hypoxic-ischaemic encephalopathy (HIE) is an important cause of morbidity and mortality in neonates. When the gold standard MRI is not feasible, cerebral ultrasound (CUS) might offer an alternative. In this study, the association between a novel CUS scoring system and neurodevelopmental outcome in neonates with HIE was assessed.
METHODS
(Near-)term infants with HIE and therapeutic hypothermia, a CUS on day 1 and day 3-7 after birth and available outcome data were retrospectively included in cohort I. CUS findings on day 1 and day 3-7 were related to adverse outcome in univariate and the CUS of day 3-7 also in multivariable logistic regression analyses. The resistance index, the sum of deep grey matter and of white matter involvement were included in multivariable logistic regression analyses. A comparable cohort from another hospital was used for validation (cohort II).
RESULTS
Eighty-three infants were included in cohort I and 35 in cohort II. The final CUS scoring system contained the sum of white matter (OR = 2.6, 95% CI 1.5-4.7) and deep grey matter involvement (OR = 2.7, 95% CI 1.7-4.4). The CUS scoring system performed well in cohort I (AUC = 0.90) and II (AUC = 0.89).
CONCLUSION
This validated CUS scoring system is associated with neurodevelopmental outcome in neonates with HIE.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.