MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/s41598-026-55886-y

Медицинская библиотека · Scientific reports · 2026

Quantitative assessment of thoracolumbosacral orthosis efficacy on the temporal features of gait using inertial measurement unit sensors.

Gull Zahra, Waris Asim, Chen Xing, Ijaz Muhammad Anees, Khan Muhammad Jawad, Ijaz Muhammad Adeel, Alanazi Falah, Ansari Khalid, Gilani Syed Omer

СтатьяРандомизированное исследованиеПеревод в очереди

Аннотация

Prolonged sitting with poor spinal posture alter the biomechanics of spine and the whole body, alleviating gait efficiency and causing fatigue. Evidence suggest that spinal braces can correct postural deviations, enhance proprioception, postural control, and spinal stability. However, the impact of an abnormal posture and spinal brace on the temporal features of gait remains unexplored. This study aimed to assess the quantitative effectiveness of spinal brace on the temporal features of gait using IMU sensors. This randomized crossover experimental study involved 15 lab workers who performed gait trials under two walking conditions: with an abnormal posture, with spinal brace. Temporal gait parameters were analyzed at baseline and post intervention using 10-Meters Walk Tests using foot worn IMU sensors. A paired t-test (p < 0.05) was utilized to compare walking conditions, and Cohen's d quantified the spinal brace's effect on gait parameters. Wearing the brace resulted in improved gait symmetry index (p < 0.001, d= -2.54), stride time (p = 0.02, d= -0.29), stance time (p = 0.012, d= -0.57) and cadence (p = 0.048, d = 0.30), with spinal stability and walking efficiency reported by our participants. These findings suggest that the spinal brace is effective in improving gait efficiency in people with postural deviations.

Для цитирования: Gull Zahra, Waris Asim, Chen Xing, Ijaz Muhammad Anees, Khan Muhammad Jawad, Ijaz Muhammad Adeel, Alanazi Falah, Ansari Khalid, Gilani Syed Omer. Quantitative assessment of thoracolumbosacral orthosis efficacy on the temporal features of gait using inertial measurement unit sensors.. Scientific reports. 2026. DOI: 10.1038/s41598-026-55886-y.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.