MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1017/s1047951112002193

Медицинская библиотека · Cardiology in the young · 2013

Flow-sensitive four-dimensional velocity-encoded magnetic resonance imaging reveals abnormal blood flow patterns in the aorta and pulmonary trunk of patients with transposition.

Riesenkampff Eugénie, Nordmeyer Sarah, Al-Wakeel Nadya, Kropf Siegfried, Kutty Shelby, Berger Felix, Kuehne Titus

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND AND

OBJECTIVES

Flow profiles are important determinants of fluid-vessel wall interactions. The aim of this study was to assess blood flow profiles in the aorta and pulmonary trunk in patients with transposition and different ventriculoarterial connection, and hence different mechanics of the coherent pump.

METHODS

In all, 29 patients with operated transposition--concordant atrioventricular and discordant ventriculoarterial connection, and no other cardiac malformation--and eight healthy volunteers were assessed with cardiac magnetic resonance imaging: n = 17 patients after atrial redirection, with a morphologic right ventricle acting as systemic pump and a morphologic left ventricle connected to the pulmonary trunk, and n = 12 patients after the arterial switch procedure, with physiologic ventriculoarterial connections. Flow-sensitive four-dimensional velocity-encoded magnetic resonance imaging was used to analyse systolic flow patterns in the aorta and pulmonary trunk, relating to helical flow and vortex formation.

RESULTS

In the aorta, overall helicity was present in healthy volunteers, but it was absent in all patients independent on the operation technique. Partial helices were observed in the ascending aorta of 58% of patients after arterial switch. In the pulmonary trunk, mostly parallel flow was seen in healthy volunteers and in patients after arterial switch, whereas vortex formation was present in 88% of patients after atrial redirection.

CONCLUSION

Blood flow patterns differ substantially between the groups. In addition to varying mechanics of the coherent pumping ventricles, the absent overall helicity in all patients might be explained by the missing looping of the aorta in transposition.

Для цитирования: Riesenkampff Eugénie, Nordmeyer Sarah, Al-Wakeel Nadya, Kropf Siegfried, Kutty Shelby, Berger Felix, Kuehne Titus. Flow-sensitive four-dimensional velocity-encoded magnetic resonance imaging reveals abnormal blood flow patterns in the aorta and pulmonary trunk of patients with transposition.. Cardiology in the young. 2013. DOI: 10.1017/s1047951112002193.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.