In-depth performance analysis of an EEG based neonatal seizure detection algorithm.

Mathieson S, Rennie J, Livingstone V, Temko A, Low E, Pressler R M, Boylan G B

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

To describe a novel neurophysiology based performance analysis of automated seizure detection algorithms for neonatal EEG to characterize features of detected and non-detected seizures and causes of false detections to identify areas for algorithmic improvement.

METHODS

EEGs of 20 term neonates were recorded (10 seizure, 10 non-seizure). Seizures were annotated by an expert and characterized using a novel set of 10 criteria. ANSeR seizure detection algorithm (SDA) seizure annotations were compared to the expert to derive detected and non-detected seizures at three SDA sensitivity thresholds. Differences in seizure characteristics between groups were compared using univariate and multivariate analysis. False detections were characterized.

RESULTS

The expert detected 421 seizures. The SDA at thresholds 0.4, 0.5, 0.6 detected 60%, 54% and 45% of seizures. At all thresholds, multivariate analyses demonstrated that the odds of detecting seizure increased with 4 criteria: seizure amplitude, duration, rhythmicity and number of EEG channels involved at seizure peak. Major causes of false detections included respiration and sweat artefacts or a highly rhythmic background, often during intermediate sleep.

CONCLUSION

This rigorous analysis allows estimation of how key seizure features are exploited by SDAs.

SIGNIFICANCE: This study resulted in a beta version of ANSeR with significantly improved performance.

Для цитирования: Mathieson S, Rennie J, Livingstone V, Temko A, Low E, Pressler R M, Boylan G B. In-depth performance analysis of an EEG based neonatal seizure detection algorithm.. Clinical neurophysiology : official journal of the International Federation of Clinical Neurophysiology. 2016. DOI: 10.1016/j.clinph.2016.01.026.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.