Patel Aara, Hayward Jane D, Tailor Vijay, Nyanhete Rodney, Ahlfors Helena, Gabriel Camila, Jannini Tommaso B, Abbou-Rayyah Yassir, Henderson Robert, Nischal Ken K, Islam Lily, Bitner-Glindzicz Maria, Hurst Jane, Valdivia Leonardo E, Zanolli Mario, Moosajee Mariya, Brookes John, Papadopoulos Maria, Khaw Peng T, Cullup Thomas, Jenkins Lucy, Dahlmann-Noor Annegret, Sowden Jane C

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: To develop a comprehensive next-generation sequencing panel assay that screens genes known to cause developmental eye disorders and inherited eye disease and to evaluate its diagnostic yield in a pediatric cohort with malformations of the globe, anterior segment anomalies, childhood glaucoma, or a combination thereof.

DESIGN

Evaluation of diagnostic test.

PARTICIPANTS

Two hundred seventy-seven children, 0 to 16 years of age, diagnosed with nonsyndromic or syndromic developmental eye defects without a genetic diagnosis.

METHODS

We developed a new oculome panel using a custom-designed Agilent SureSelect QXT target capture method (Agilent Technologies, Santa Clara, CA) to capture and perform parallel high-throughput sequencing analysis of 429 genes associated with eye disorders. Bidirectional Sanger sequencing confirmed suspected pathogenic variants.

MAIN OUTCOME MEASURES: Collated clinical details and oculome molecular genetic results.

RESULTS

The oculome design covers 429 known eye disease genes; these are subdivided into 5 overlapping virtual subpanels for anterior segment developmental anomalies including glaucoma (ASDA; 59 genes), microphthalmia-anophthalmia-coloboma (MAC; 86 genes), congenital cataracts and lens-associated conditions (70 genes), retinal dystrophies (RET; 235 genes), and albinism (15 genes), as well as additional genes implicated in optic atrophy and complex strabismus (10 genes). Panel development and testing included analyzing 277 clinical samples and 3 positive control samples using Illumina sequencing platforms; more than 30× read depth was achieved for 99.5% of the targeted 1.77-Mb region. Bioinformatics analysis performed using a pipeline based on Freebayes and ExomeDepth to identify coding sequence and copy number variants, respectively, resulted in a definitive diagnosis in 68 of 277 samples, with variability in diagnostic yield between phenotypic subgroups: MAC, 8.2% (8 of 98 cases solved); ASDA, 24.8% (28 of 113 cases solved); other or syndromic, 37.5% (3 of 8 cases solved); RET, 42.8% (21 of 49 cases solved); and congenital cataracts and lens-associated conditions, 88.9% (8 of 9 cases solved).

CONCLUSIONS

The oculome test diagnoses a comprehensive range of genetic conditions affecting the development of the eye, potentially replacing protracted and costly multidisciplinary assessments and allowing for faster targeted management. The oculome enabled molecular diagnosis of a significant number of cases in our sample cohort of varied ocular birth defects.

Для цитирования: Patel Aara, Hayward Jane D, Tailor Vijay, Nyanhete Rodney, Ahlfors Helena, Gabriel Camila, Jannini Tommaso B, Abbou-Rayyah Yassir, Henderson Robert, Nischal Ken K, Islam Lily, Bitner-Glindzicz Maria, Hurst Jane, Valdivia Leonardo E, Zanolli Mario, Moosajee Mariya, Brookes John, Papadopoulos Maria, Khaw Peng T, Cullup Thomas, Jenkins Lucy, Dahlmann-Noor Annegret, Sowden Jane C. The Oculome Panel Test: Next-Generation Sequencing to Diagnose a Diverse Range of Genetic Developmental Eye Disorders.. Ophthalmology. 2019. DOI: 10.1016/j.ophtha.2018.12.050.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.