Comparison of two percutaneous volar approaches for screw fixation of scaphoid waist fractures: radiographic and biomechanical study of an osteotomy-simulated model.

Meermans Geert, Van Glabbeek Francis, Braem Marc J, van Riet Roger P, Hubens Guy, Verstreken Frederik

Сравнительное исследованиеСтатьяРандомизированное исследованиеVideo-Audio MediaПеревод в очереди

Аннотация

BACKGROUND

When a surgeon uses a percutaneous volar approach to treat scaphoid waist fractures, central screw placement is complicated by the shape of the scaphoid and by obstruction by the trapezium. In this study, we used radiographs and biomechanical tests to compare the standard volar percutaneous approach with the transtrapezial approach, with regard to central screw placement at the distal pole of the scaphoid.

METHODS

Fourteen matched pairs of cadaveric wrists were randomly assigned to two treatment groups. Under fluoroscopic control, a guidewire was drilled into the scaphoid, either through a transtrapezial approach or through a standard volar approach that avoided the trapezium. Guidewire position was measured in the coronal and sagittal planes. A transverse osteotomy was performed along the scaphoid waist, and this was followed by the insertion of the longest possible cannulated headless bone screw. Each specimen was placed into a fixture with a pneumatically driven plunger resting on the surface of the distal pole. Load was applied by using a load-controlled test protocol in a hydraulic testing machine.

RESULTS

All guidewires were inside the central one-third of the proximal pole. The guidewire positions at the distal pole differed significantly between the transtrapezial and standard volar approach groups (p < 0.001). The load to 2 mm of displacement and the load to failure averaged, respectively, 324.4 N (standard error of the mean [SEM] = 73.5 N) and 386.4 N (SEM = 65.6 N) for the transtrapezial approach group compared with 125.7 N (SEM = 22.6 N) (p = 0.002) and 191.4 N (SEM = 36.30 N) (p = 0.005) for the standard volar approach group.

CONCLUSIONS

The data suggest that, in a cadaveric osteotomy-simulated scaphoid waist fracture model, the transtrapezial approach reliably achieves central positioning of a screw in the proximal and distal poles. This position offers a biomechanical advantage compared with central placement in only the proximal pole.

Для цитирования: Meermans Geert, Van Glabbeek Francis, Braem Marc J, van Riet Roger P, Hubens Guy, Verstreken Frederik. Comparison of two percutaneous volar approaches for screw fixation of scaphoid waist fractures: radiographic and biomechanical study of an osteotomy-simulated model.. The Journal of bone and joint surgery. American volume. 2014. DOI: 10.2106/jbjs.l.01729.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.