MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1302/0301-620x.73b1.1991784

Медицинская библиотека · The Journal of bone and joint surgery. British volume · 1991

The use of a tourniquet when plating tibial fractures.

Salam A A, Eyres K S, Cleary J, el-Sayed H H

СтатьяПеревод в очереди

Аннотация

Sixty closed fractures of the tibia were treated by open reduction and internal fixation with plates and screws. Half the operations were performed with a thigh tourniquet and half without. In the tourniquet group, there were six cases with erythema and induration of the wound; in the other group there were no such complications. Despite negative bacterial cultures, superficial infection of the inflamed wounds was suspected. It is suggested that a tourniquet may predispose tissues to infection, and its use is not recommended during operations for internal fixation of the tibia.

Для цитирования: Salam A A, Eyres K S, Cleary J, el-Sayed H H. The use of a tourniquet when plating tibial fractures.. The Journal of bone and joint surgery. British volume. 1991. DOI: 10.1302/0301-620x.73b1.1991784.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.