m+Medelevator.RU
← Поиск публикаций
Urology · 2014

Revascularization of living-donor kidney transplant with multiple arteries: long-term outcomes using the inferior epigastric artery.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Antonopoulos Ioannis M, Yamaçake Kleiton Gabriel Ribeiro, Oliveira Lorena M, Piovesan Affonso C, Kanashiro Hideki, Nahas Willian C

Аннотация

OBJECTIVE: To study the safety and long-term outcomes of use of the inferior epigastric artery (IEA) for revascularization of small accessory kidney arteries (3 mm or less).

MATERIALS AND METHODS: Data of 602 living-donor kidney transplants were reviewed. Age was 37.4 ± 15 years (range, 3-78 years). Multiple arteries were present in 98 kidneys (16.3%); of these, 83 (84.7%) had 2 and arteries and 15 (15.3%) had 3 arteries. In 21 kidneys (21.4%) with multiple arteries (group I [GI]), the IEA was used for reconstruction. Four (14.3%) had 3 arteries, and 17 (85.7%) had 2 arteries. In 77 patients (group II [GII]), the inferior accessory renal artery was reconstructed with a side-to-side or an end-to-side anastomosis to the main renal artery. Follow-up was 43.8 ± 38.1 months (range, 1-124 months). The Fisher exact test and the 2-tailed t test were used for statistical analysis.

RESULTS: Delayed graft function occurred in 1 GI patient (4.8%) and in 5 GII patients (6.5%; P >.05). One partial renal infarction occurred in each group (4.8% vs 1.3%; P >.05). There was 1 urinary fistula in GI and 3 urinary fistulas and 1 ureteral stenosis in GII (P >.05). One graft (4.8%) lost function in GI and 5 (6.5%) in GII (P >.05). Eleven patients (53.4%) were hypertensive in GI and 53 (68.8%) in GII (P >.05).

CONCLUSION: The use of the IEA for revascularization of a living-donor kidney transplant with multiple arteries is safe and effective, yielding similar long-term outcomes compared with the standard technique. Use of the IEA avoids the risks of manipulation of the main renal artery.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты