Xia C, Kang M, Zhu W, Wang J, Bao D, Zhou Y, Gong F

Аннотация

OBJECTIVE: To estimate the effect of percutaneous balloon pulmonary valvuloplasty (PBPV) using domestic balloon catheter for congenital pulmonary valve stenosis (PVS) in infants and children.

PATIENTS AND METHODS: The data of 70 patients aged from 1.5 to 12 years (mean 5.5 +/- 3.4 years) who underwent PBPV using domestic balloon catheter for PVS in our institution were reviewed. Sixty-six patients had dome-shaped valve stenosis, and 4 had displastic valve stenosis. SaO2 reduced in 5 patients and associated open foramen ovale was noted in 23. Predilatation, right ventricular systolic pressure ranged from 60 to 234 mmHg (mean 115.75 +/- 36.15 mmHg). The systolic gradient (delta P) from right ventricle to pulmonary artery was 89.92 +/- 38.25 mmHg. Balloon diameter was selected 120%-142% of pulmonary valve annulus diameter (mean 132%). All patients were followed up for 3 months-4 years by means of clinical examination. ECG, 2D-UCG, and Doppler-UCG.

RESULTS: After dilatation, delta P reduced from 89.92 +/- 38.25 to 14.65 +/- 11.40 mmHg (P < 0.001). The rate of decrease in transvalve gradient (delta P) was 83.7%. No patients experienced procedure-related events. Mid-term follow-up showed that no patients had clinical and instrumental complications. Doppler and ECG analyses showed that delta P did not change significantly similar to immediate gradient after PBPV and right ventricular hypertrophy disappeared progressively 6 months after PBPV.

CONCLUSIONS: PBPV is a useful, safe and definitive procedure in the treatment of isolated PVS in infants and children. The properties and features of the balloon catheter produced by Shanghai Med-Tech Factory are similar to those of Med-Tech balloon catheter of U.S.A.