MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.healun.2016.11.007

Медицинская библиотека · The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation · 2016

Cardiac dysfunction in children and young adults with heart transplantation: A comprehensive echocardiography study.

Chinali Marcello, Esposito Claudia, Grutter Giorgia, Iacobelli Roberta, Toscano Alessandra, D'Asaro Maria Grazia, Pasqua Alessia Del, Brancaccio Gianluca, Parisi Francesco, Drago Fabrizio, Rinelli Gabriele

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

BACKGROUND

Transplanted heart dysfunction is a serious life-threatening condition in pediatric transplant recipients. Several studies have focused on echocardiographic detection of early signs of cardiac dysfunction in this population. We evaluated advanced echocardiographic indices of cardiac function in a large sample of children and young adults with heart transplants with apparently normal cardiac function.

METHODS

The study included 60 patients with normal ejection fraction with transplantation performed at pediatric age between 1986 and 2014 and 60 healthy control subjects. All patients and control subjects underwent a complete transthoracic echocardiographic examination including tissue Doppler analysis, 2-dimensional speckle tracking, and 3-dimensional echocardiography. Two-dimensional speckle tracking analysis was used to obtain measures of left ventricular (LV) radial, circumferential, and longitudinal strain and to derive LV twist and torsion from basal and apical rotation. Three-dimensional echocardiography was used to measure LV volumes and ejection fraction and to evaluate LV systolic synchrony.

RESULTS

No differences were observed between groups in LV volumes, left atrial diameters, LV ejection fraction, or right ventricular fractional area change. However, patients showed lower values of longitudinal systolic excursion of valvular planes at both the mitral and the tricuspid valve level as well as higher mitral E/E' ratio. Cardiac radial strain was similar between groups; a significant net reduction in both global left and right ventricular longitudinal strain and LV global circumferential strain could be observed between the 2 groups (all p < 0.05). In addition, reduced LV twist and torsion was found in patients compared with healthy control subjects (p < 0.01) mainly owing to a significant reduction in basal rotation (-2.4° vs -3.8°; p < 0.05). none of the control subjects demonstrated LV dyssynchrony, whereas systolic dyssynchrony was observed in 20% of heart transplant recipients.

CONCLUSIONS

Even in the absence of signs of graft failure and in the presence of a normal ejection fraction, transplanted hearts show a significant reduction in biventricular function. Additional prognostic studies are needed to establish whether these abnormalities predict development of overt heart failure.

Для цитирования: Chinali Marcello, Esposito Claudia, Grutter Giorgia, Iacobelli Roberta, Toscano Alessandra, D'Asaro Maria Grazia, Pasqua Alessia Del, Brancaccio Gianluca, Parisi Francesco, Drago Fabrizio, Rinelli Gabriele. Cardiac dysfunction in children and young adults with heart transplantation: A comprehensive echocardiography study.. The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation. 2016. DOI: 10.1016/j.healun.2016.11.007.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.