MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/j.1471-0528.1995.tb10903.x

Медицинская библиотека · British journal of obstetrics and gynaecology · 1995

The value of fetal arterial, cardiac and venous flows in predicting pH and blood gases measured in umbilical blood at cordocentesis in growth retarded fetuses.

Rizzo G, Capponi A, Arduini D, Romanini C

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

To assess the value of Doppler indices, calculated from fetal arterial peripheral vessels, cardiac outflow tracts and venous vessels, in the identification of acidaemia, hypercapnia and hypoxaemia as determined by pH and gas analysis of fetal blood obtained by cordocentesis in growth retarded fetuses.

DESIGN

Doppler measurements were taken from umbilical artery, thoracic descending aorta, renal artery, middle cerebral artery, cardiac outflow tracts, inferior vena cava and ductus venosus immediately before cordocentesis. Logistic regression and receiver-operator characteristic curve analysis were performed to examine the relation between Doppler indices and acid-base status.

SETTING

Tertiary centre for fetal medicine.

SUBJECTS: Forty-eight growth retarded fetuses fulfilling these criteria for inclusion: 1. absence of chromosomal and structural anomalies; 2. an abdominal circumference or ultrasonographic estimated fetal weight less than the 5th centile; 3. presence of abnormal velocity waveforms in umbilical artery; and 4. postnatal confirmation of a birthweight below the 5th centile and absence of structural anomalies.

RESULTS

The percentage of reverse flow in inferior vena cava was a more closely related variable for acidaemia (chi 2 = 29.69; P < or = 0.001) and hypercapnia (chi 2 = 12.86; P < or = 0.001) than the other Doppler indices. Hypoxaemia was better predicted by the pulsatility index from middle cerebral artery (chi 2 = 15.31; P < or = 0.001).

CONCLUSION

The analysis of velocity waveforms from inferior vena cava and middle cerebral artery can be used to predict acid-base status in growth retarded fetuses secondary to placental insufficiency. This may lead to a more accurate antepartum monitoring of such fetuses.

Для цитирования: Rizzo G, Capponi A, Arduini D, Romanini C. The value of fetal arterial, cardiac and venous flows in predicting pH and blood gases measured in umbilical blood at cordocentesis in growth retarded fetuses.. British journal of obstetrics and gynaecology. 1995. DOI: 10.1111/j.1471-0528.1995.tb10903.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.