MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00402-025-06137-8

Медицинская библиотека · Archives of orthopaedic and trauma surgery · 2025

Three-years comparative outcomes of S-ROM versus Wagner cone prostheses in total hip arthroplasty with subtrochanteric osteotomy for Crowe IV hip dysplasia.

Wang Kunhao, Zhang Tao, Xia Ruiyang, Wang Jiankai, Wang Wenbo

СтатьяСравнительное исследованиеПеревод в очереди

Аннотация

BACKGROUND

Total hip arthroplasty (THA) with subtrochanteric osteotomy is a common approach for managing Crowe IV developmental dysplasia of the hip (DDH). This study compares the efficacy and safety of S-ROM and Wagner cone prostheses in this procedure.

METHODS

A retrospective study analyzed 68 patients (75 hips) with Crowe IV DDH who underwent THA with subtrochanteric osteotomy between 2013 and 2021, with a minimum 3-year follow-up. Patients were divided into two groups: 36 patients (38 hips) received S-ROM prostheses, and 32 patients (37 hips) received Wagner cone prostheses. Outcomes including surgical duration, intraoperative blood loss, postoperative complications, Harris Hip Score (HHS), Visual Analog Scale (VAS) scores, osteotomy healing time, and factors associating healing were compared.

RESULTS

The Wagner cone group had significantly shorter surgical duration and less intraoperative blood loss compared to the S-ROM group. At 3 years, the S-ROM group showed higher HHS and slightly lower VAS scores. Osteotomy healing rates were comparable, but the S-ROM group had shorter healing times. Complication rates were 10.5% (4/38 hips) for S-ROM and 18.9% (7/37 hips) for Wagner cone. Preoperative HHS was an independent predictor of osteotomy healing (OR: 0.611, 95% CI: 0.448–0.832, P = 0.002).

CONCLUSION

The Wagner cone prosthesis reduces surgical duration and blood loss, while the S-ROM prosthesis offers superior functional outcomes and faster osteotomy healing. Both prostheses demonstrate comparable safety and healing rates, making them suitable for Crowe IV DDH.

Для цитирования: Wang Kunhao, Zhang Tao, Xia Ruiyang, Wang Jiankai, Wang Wenbo. Three-years comparative outcomes of S-ROM versus Wagner cone prostheses in total hip arthroplasty with subtrochanteric osteotomy for Crowe IV hip dysplasia.. Archives of orthopaedic and trauma surgery. 2025. DOI: 10.1007/s00402-025-06137-8.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.