MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/aogs.12308

Медицинская библиотека · Acta obstetricia et gynecologica Scandinavica · 2014

The viscoelastic properties of the cervical mucus plug.

Bastholm Sara K, Becher Naja, Stubbe Peter R, Chronakis Ioannis S, Uldbjerg Niels

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

To characterize the viscoelastic properties of cervical mucus plugs(CMPs) shed during labor at term.

DESIGN

Experimental research.

SETTING

Department of Obstetrics and Gynecology, Aarhus University Hospital, Denmark.

POPULATION/SAMPLE: Spontaneously shed CMPs from 18 healthy women in active labor.

METHODS

Viscoelastic properties of CMPs were investigated with a dynamic oscillatory rheometer using frequency and stress sweep experiments within the linear viscoelastic region.

MAIN OUTCOME MEASURES: The rheological variables obtained were as follows: elastic modulus (G′), viscous modulus (G″) and tan delta (G″/G′). Random-effects regression was used for statistical analysis.

RESULTS

All CMPs showed solid-like viscoelastic behavior.This was substantiated by the elastic modulus which was three to four times greater than the viscous modulus and by tan delta, which was <1 at all frequencies.Mean tan delta at 0.01 Hz was 0.38 (95% CI 0.34-0.43) and 0.27(95% CI 0.23-0.32) at 1 Hz. The elastic modulus could be described by the relation G′(ω) = K(ω)(A) [mean R2 0.95 (95% CI 0.93-0.98)]. Despite relatively large variation in the rheological properties within CMPs, rheological variables obtained from frequency sweeps differed significantly among CMPs (p < 0.05).

CONCLUSION

The CMPs are solid-like viscoelastic structures. These rheological characteristics are probably essential for the CMP's ability to form and sustain a plug in the cervical canal during pregnancy, thereby reducing the risk of ascending infections. The technique described here might be used for evaluation of an association between CMP viscoelasticity and preterm delivery.

Для цитирования: Bastholm Sara K, Becher Naja, Stubbe Peter R, Chronakis Ioannis S, Uldbjerg Niels. The viscoelastic properties of the cervical mucus plug.. Acta obstetricia et gynecologica Scandinavica. 2014. DOI: 10.1111/aogs.12308.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.