Journal of AOAC International · 2018
Validation of Biomode S.A. Probe4CronobacterTM for the Identification of Cronobacter spp.
СтатьяВалидационное исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Sousa J Mário, Rocha Rui, Cerqueira Laura, Almeida Carina, Azevedo Nuno F, Bastin Benjamin, Bird Patrick, Benzinger M Joseph, Agin James, Goins David, Chen Yi, Brodsky Michael, Odumoru Joseph
Аннотация
Background: Probe4Cronobacter test kit is based on the use of a fluorescence-labeled peptide nucleic acid probe (PNA) allied to fluorescence microscopy. A sample is taken after a 24 h enrichment of rehydrated 30 g portions of powdered infant formula (PIF). The method uses ready to use dropper solutions applied directly in the sample. This simple process takes less than 2 h to provide a result. In the presence of Cronobacter species, bright red rod-shaped cells will be visible under a fluorescence microscope. Objective: Probe4Cronobacter validation as a new method for the detection Cronobacter species in Powdered Infant Formula (PIF) under the AOAC Performance Tested MethodsSM (License No. 081702). Methods: The validation study encompassed matrix comparison study, inclusivity and exclusivity testing and robustness studies (stability, kit variation, and ruggedness). Results: The inclusivity and exclusivity testing (50 and 35 strains, respectively) yielded no false negative or false positive results. Probe4Cronobacter was compared to the ISO/TS 22964:2006 in 30 g of PIF samples within method comparison in an unpaired study. A total of 30 samples with both low and high level of inoculation were analyzed by Probe4Cronobacter and compared to the same number of samples screened by ISO/TS 22964:2006. No statistically significant differences between presumptive and confirmed results or between candidate and reference method results were observed. Robustness studies showed a high level of consistency and integrity of the kit when different parameters were varied. The deviation conditions tested did not affect the performance of the kit. Conclusions: Probe4Cronobacter test kit has shown to be a accurate, highly sensitive and robust methods for the detection of Cronobacter spp. in PIF samples.