MedElevator Войти в исследования
← Поиск публикаций

DOI 10.5740/jaoacint.18-0328

Медицинская библиотека · Journal of AOAC International · 2018

Validation of Biomode S.A. Probe4CronobacterTM for the Identification of Cronobacter spp.

Sousa J Mário, Rocha Rui, Cerqueira Laura, Almeida Carina, Azevedo Nuno F, Bastin Benjamin, Bird Patrick, Benzinger M Joseph, Agin James, Goins David, Chen Yi, Brodsky Michael, Odumoru Joseph

СтатьяВалидационное исследованиеПеревод в очереди

Аннотация

Background

Probe4Cronobacter test kit is based on the use of a fluorescence-labeled peptide nucleic acid probe (PNA) allied to fluorescence microscopy. A sample is taken after a 24 h enrichment of rehydrated 30 g portions of powdered infant formula (PIF). The method uses ready to use dropper solutions applied directly in the sample. This simple process takes less than 2 h to provide a result. In the presence of Cronobacter species, bright red rod-shaped cells will be visible under a fluorescence microscope.

Objective

Probe4Cronobacter validation as a new method for the detection Cronobacter species in Powdered Infant Formula (PIF) under the AOAC Performance Tested MethodsSM (License No. 081702).

Methods

The validation study encompassed matrix comparison study, inclusivity and exclusivity testing and robustness studies (stability, kit variation, and ruggedness).

Results

The inclusivity and exclusivity testing (50 and 35 strains, respectively) yielded no false negative or false positive results. Probe4Cronobacter was compared to the ISO/TS 22964:2006 in 30 g of PIF samples within method comparison in an unpaired study. A total of 30 samples with both low and high level of inoculation were analyzed by Probe4Cronobacter and compared to the same number of samples screened by ISO/TS 22964:2006. No statistically significant differences between presumptive and confirmed results or between candidate and reference method results were observed. Robustness studies showed a high level of consistency and integrity of the kit when different parameters were varied. The deviation conditions tested did not affect the performance of the kit.

Conclusions

Probe4Cronobacter test kit has shown to be a accurate, highly sensitive and robust methods for the detection of Cronobacter spp. in PIF samples.

Для цитирования: Sousa J Mário, Rocha Rui, Cerqueira Laura, Almeida Carina, Azevedo Nuno F, Bastin Benjamin, Bird Patrick, Benzinger M Joseph, Agin James, Goins David, Chen Yi, Brodsky Michael, Odumoru Joseph. Validation of Biomode S.A. Probe4CronobacterTM for the Identification of Cronobacter spp.. Journal of AOAC International. 2018. DOI: 10.5740/jaoacint.18-0328.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.