Role of cardiovascular magnetic resonance end-systolic 3D-SSFP sequence in repaired tetralogy of Fallot patients eligible for transcatheter pulmonary valve implantation.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Leonardi Benedetta, Secinaro Aurelio, Perrone Marco Alfonso, Curione Davide, Napolitano Carmela, Gagliardi Maria Giulia
Аннотация
To evaluate the usefulness of cardiovascular magnetic resonance (CMR) 3D steady state free precession (SSFP) sequence acquired at end-systole (ES) in repaired Tetralogy of Fallot (rToF) patients eligible for percutaneous pulmonary valve implantation (PPVI). Between 2012 and 2018, 78 rToF patients were selected for pulmonary valve replacement (PVR) according to CMR criteria. CMR protocol included 3D-SSFP sequence used to assess the right ventricle outflow tract (RVOT) diameters at three levels (pulmonary valve remnant, mid-portion, bifurcation) in mid-diastole (MD) or ES, RVOT length and coronary artery anatomy. In 20 rToF patients without indications for PVR (controls), 3D SSFP sequence was acquired at both cardiac phases (MD and ES) to evaluate RVOT dimension throughout the cardiac cycle. Invasive balloon sizing was recorded in patients undergoing PPVI. The 3D-SSFP sequence was performed in MD on 39 patients and in ES on other 39, of whom 26 patients met the criteria for PPVI. The latter was unsuccessful in ten patients (38%), mainly due (80% of cases) to significant size discrepancy at PV remnant and bifurcation levels (p = 0.019 and 0.037 respectively) between the measurements by 3D-SSFP in MD and those by the balloon size in systole. Significant RVOT size difference between MD and ES was present at mid-portion and bifurcation levels in the PVR candidate group, and at all three-levels in the control group (all p < 0.001). ES 3D-SSFP sequence is able to quantify RVOT dilation in rToF patients at its maximum expansion, thus improving selection of PPVI candidates.
Предметные рубрики MeSH
AdolescentBalloon ValvuloplastyCardiac CatheterizationCardiac Surgical ProceduresChildClinical Decision-MakingFemaleHeart Valve ProsthesisHeart Valve Prosthesis ImplantationHemodynamicsHumansImage Interpretation, Computer-AssistedMagnetic Resonance Imaging, CineMaleObserver VariationPatient SelectionPredictive Value of TestsProsthesis DesignPulmonary CirculationPulmonary Valve InsufficiencyReproducibility of ResultsRetrospective StudiesTetralogy of FallotTreatment OutcomeYoung Adult