MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00256-026-05158-7

Медицинская библиотека · Skeletal radiology · 2026

Tin-filtered ultra-low-dose CT for lower limb torsion measurements in children and adolescents: a prospective study.

Markart Stefan, Griessinger Jennifer, Graf Nicole, Leschka Sebastian, Cip Johannes, Dietrich Tobias Johannes, Wälti Stephan

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

Accurate femoral and tibial torsion measurements are essential for planning lower extremity derotation surgeries in children/adolescents. Advances in modern CT scanners may enable reliable measurements using tin filtration in addition to an ultra-low-dose CT protocol, markedly reducing radiation exposure. This study evaluates image quality, reliability, and estimated effective radiation dose of this approach.

MATERIALS AND

METHODS

Between April 2022 and December 2022, tin-filtered ultra-low-dose CTs were prospectively acquired from 52 children/adolescents using a 384-slice scanner. Two pediatric radiologists independently performed torsion measurements for all patients. Interrater agreement and image quality were assessed. Effective radiation doses of the scans were estimated.

RESULTS

The study population consisted of 52 participants (mean age, 12.7 years ± 2.0 [standard deviation]; 19 females, 33 males). All torsion measurements showed very high interrater agreement (intra-class correlation coefficient > 90% for all locations). The image quality of the vast majority of image datasets was rated as excellent. The mean total effective dose of the tin filtered ultra-low-dose protocol (including 3 spiral scans) was 0.026/0.025 mSv (boys/girls), compared to 0.184/0.215 mSv (boys/girls) of the previously published ultra-low-dose protocol without tin filtration. This represents a dose reduction of up to 88% compared to the previous protocol.

CONCLUSION

The use of tin filtration, in addition to an ultra-low-dose protocol, allows pediatric lower extremity torsion measurements to be performed with radiation doses in a lower range than a typical localizer dose, without compromising diagnostic confidence, pushing the limits of the ALARA (as low as reasonably achievable) principle.

Для цитирования: Markart Stefan, Griessinger Jennifer, Graf Nicole, Leschka Sebastian, Cip Johannes, Dietrich Tobias Johannes, Wälti Stephan. Tin-filtered ultra-low-dose CT for lower limb torsion measurements in children and adolescents: a prospective study.. Skeletal radiology. 2026. DOI: 10.1007/s00256-026-05158-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.