MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/mao.0000000000002210

Медицинская библиотека · Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology · 2019

A New Lateral Wall Electrode: Evaluation of Surgical Handling, Radiographic Placement, and Histological Appraisal of Insertion Trauma.

Rivas Alejandro, Yawn Robert J, Kim Ana H, Driscoll Colin, Cullen Robert, Rebscher Stephen J, Isaacson Brandon

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

To describe histologic and radiographic findings associated with insertion of a new lateral wall electrode in human temporal bones, as well as quantify the ease of insertion as characterized by multiple cochlear implant surgeons.

SETTING

Multi-institutional cadaveric study.

METHODS

The Slim J electrode was inserted in cadaveric temporal bones via a standard mastoidectomy and facial recess approach. Insertion was performed by five cochlear implant surgeons with no previous experience with the Slim J electrode array. Electrode array insertion was performed via a round window, an extended round window, or a cochleostomy approach. Intracochlear trauma, and angular insertion depth was assessed histologically and radiologically, respectively, after placement of the Slim J electrode array.

RESULTS

Scala tympani insertion was accomplished in all 40 specimens. Thirty-eight specimens (95%) showed minimal trauma (Esrhaghi grade 0 or 1). One patient had rupture of basilar membrane (grade 2 trauma) at 380 degrees. One patient had grade 4 trauma with scalar translocation beginning at 210 degrees. The mean angular insertion depth was 416.4 degrees (range: 338.7-509.2 degrees, SD 44 degrees). Surgical handling was described as easy in 38 cases (95%).

CONCLUSION

In a human cadaveric model the lateral wall Slim J electrode produced minimal intracochlear trauma that was positioned completely within the scala tympani in 97.5% of cases.

Для цитирования: Rivas Alejandro, Yawn Robert J, Kim Ana H, Driscoll Colin, Cullen Robert, Rebscher Stephen J, Isaacson Brandon. A New Lateral Wall Electrode: Evaluation of Surgical Handling, Radiographic Placement, and Histological Appraisal of Insertion Trauma.. Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology. 2019. DOI: 10.1097/mao.0000000000002210.