DOI 10.1213/01.ane.0000166975.38649.27

Медицинская библиотека · Anesthesia and analgesia · 2005

Cervical spine motion: a fluoroscopic comparison during intubation with lighted stylet, GlideScope, and Macintosh laryngoscope.

Turkstra Timothy P, Craen Rosemary A, Pelz David M, Gelb Adrian W

Клиническое исследованиеСравнительное исследованиеСтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

The question of which is the optimum technique to intubate the trachea in a patient who may have a cervical(C)-spine injury remains unresolved. We compared, using fluoroscopic video, C-spine motion during intubation for Macintosh 3 blade, GlideScope, and Intubating Lighted Stylet, popularly known as the Lightwand or Trachlight. Thirty-six healthy patients were randomized to participate in a crossover trial of either Lightwand or GlideScope to Macintosh laryngoscopy, with in-line stabilization. C-spine motion was examined at the Occiput-C1 junction, C1-2 junction, C2-5 motion segment, and C5-thoracic motion segment during manual ventilation via bag-mask, laryngoscopy, and intubation. Time to intubate was also measured. C-spine motion during bag-mask ventilation was 82% less at the four motion segments studied than during Macintosh laryngoscopy (P < 0.001). C-spine motion using the Lightwand was less than during Macintosh laryngoscopy, averaging 57% less at the four motion segments studied (P < 0.03). There was no significant difference in time to intubate between the Lightwand and the Macintosh blade. C-spine motion was reduced 50% at the C2-5 segment using the GlideScope (P < 0.04) but unchanged at the other segments. Laryngoscopy with GlideScope took 62% longer than with the Macintosh blade (P < 0.01). Thus, the Lightwand (Intubating Lighted Stylet) is associated with reduced C-spine movement during endotracheal intubation compared with the Macintosh laryngoscope.

Для цитирования: Turkstra Timothy P, Craen Rosemary A, Pelz David M, Gelb Adrian W. Cervical spine motion: a fluoroscopic comparison during intubation with lighted stylet, GlideScope, and Macintosh laryngoscope.. Anesthesia and analgesia. 2005. DOI: 10.1213/01.ane.0000166975.38649.27.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.