MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1017/s1047951122002888

Медицинская библиотека · Cardiology in the young · 2022

Hemodynamic profile effects of PM101 amiodarone formulation in patients with post-operative tachyarrhythmias.

DeCoy Meredith, Page-Goertz Christopher, Nofziger Ryan, Besunder James, Raimer Patricia, Gothard David, Brown Miraides, Stewart Robert, Ruggles Cassandra, Breedlove Kristen, Clark John

СтатьяПеревод в очереди

Аннотация

Amiodarone may be considered for patients with junctional ectopic tachycardia refractory to treatment with sedation, analgesia, cooling, and electrolyte replacements. There are currently no published pediatric data regarding the hemodynamic effects of the newer amiodarone formulation, PM101, devoid of hypotensive agents used in the original amiodarone formulation. We performed a single-center, retrospective, descriptive study from January 2012 to December 2020 in a pediatric ICU. Thirty-three patients were included (22 male and 11 female) between the ages of 1.1 and 1,460 days who developed post-operative junctional ectopic tachycardia or other tachyarrhythmias requiring PM101. Data analysis was performed on hemodynamic parameters (mean arterial pressures and heart rate) and total PM101 (mg/kg) from hour 0 of amiodarone administration to hour 72. Adverse outcomes were defined as Vasoactive-Inotropic Score >20, patients requiring ECMO or CPR, or patient death. There was no statistically significant decrease in mean arterial pressures within the 6 hours of PM101 administration (p > 0.05), but there was a statistically significant therapeutic decrease in heart rate for resolution of tachyarrhythmia (p < 0.05). Patients received up to 25 mg/kg in an 8-hour time for rate control. Average rate control was achieved within 11.91 hours and average rhythm control within 62 hours. There were four adverse events around the time of PM101 administration, with three determined to not be associated with the medication. PM101 is safe and effective in the pediatric cardiac surgical population. Our study demonstrated that PM101 can be used in a more aggressive dosing regimen than previously reported in pediatric literature with the prior formulation.

Для цитирования: DeCoy Meredith, Page-Goertz Christopher, Nofziger Ryan, Besunder James, Raimer Patricia, Gothard David, Brown Miraides, Stewart Robert, Ruggles Cassandra, Breedlove Kristen, Clark John. Hemodynamic profile effects of PM101 amiodarone formulation in patients with post-operative tachyarrhythmias.. Cardiology in the young. 2022. DOI: 10.1017/s1047951122002888.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.