MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.echo.2013.02.018

Медицинская библиотека · Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography · 2013

Echocardiographic methods, quality review, and measurement accuracy in a randomized multicenter clinical trial of Marfan syndrome.

Selamet Tierney Elif Seda, Levine Jami C, Chen Shan, Bradley Timothy J, Pearson Gail D, Colan Steven D, Sleeper Lynn A, Campbell M Jay, Cohen Meryl S, De Backer Julie, Guey Lin T, Heydarian Haleh, Lai Wyman W, Lewin Mark B, Marcus Edward, Mart Christopher R, Pignatelli Ricardo H, Printz Beth F, Sharkey Angela M, Shirali Girish S, Srivastava Shubhika, Lacro Ronald V, Pediatric Heart Network Investigators

СтатьяМногоцентровое исследованиеПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПоддержка правительства СШАОбзорПеревод в очереди

Аннотация

BACKGROUND

The Pediatric Heart Network is conducting a large international randomized trial to compare aortic root growth and other cardiovascular outcomes in 608 subjects with Marfan syndrome randomized to receive atenolol or losartan for 3 years. The authors report here the echocardiographic methods and baseline echocardiographic characteristics of the randomized subjects, describe the interobserver agreement of aortic measurements, and identify factors influencing agreement.

METHODS

Individuals aged 6 months to 25 years who met the original Ghent criteria and had body surface area-adjusted maximum aortic root diameter (ROOTmax) Z scores > 3 were eligible for inclusion. The primary outcome measure for the trial is the change over time in ROOTmaxZ score. A detailed echocardiographic protocol was established and implemented across 22 centers, with an extensive training and quality review process.

RESULTS

Interobserver agreement for the aortic measurements was excellent, with intraclass correlation coefficients ranging from 0.921 to 0.989. Lower interobserver percentage error in ROOTmax measurements was independently associated (model R(2) = 0.15) with better image quality (P = .002) and later study reading date (P < .001). Echocardiographic characteristics of the randomized subjects did not differ by treatment arm. Subjects with ROOTmaxZ scores ≥ 4.5 (36%) were more likely to have mitral valve prolapse and dilation of the main pulmonary artery and left ventricle, but there were no differences in aortic regurgitation, aortic stiffness indices, mitral regurgitation, or left ventricular function compared with subjects with ROOTmaxZ scores < 4.5.

CONCLUSIONS

The echocardiographic methodology, training, and quality review process resulted in a robust evaluation of aortic root dimensions, with excellent reproducibility.

Для цитирования: Selamet Tierney Elif Seda, Levine Jami C, Chen Shan, Bradley Timothy J, Pearson Gail D, Colan Steven D, Sleeper Lynn A, Campbell M Jay, Cohen Meryl S, De Backer Julie, Guey Lin T, Heydarian Haleh, Lai Wyman W, Lewin Mark B, Marcus Edward, Mart Christopher R, Pignatelli Ricardo H, Printz Beth F, Sharkey Angela M, Shirali Girish S, Srivastava Shubhika, Lacro Ronald V, Pediatric Heart Network Investigators. Echocardiographic methods, quality review, and measurement accuracy in a randomized multicenter clinical trial of Marfan syndrome.. Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography. 2013. DOI: 10.1016/j.echo.2013.02.018.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.