m+Medelevator.RU
← Поиск публикаций
Computer methods and programs in biomedicine · 2026

A Multi-physics model of flow from coronary angiography: Insights to microvascular function.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Yang Haizhou, Zhang Jiyang, Assi Ismael Z, Nallamothu Brahmajee K, Garikipati Krishna, Figueroa C Alberto

Аннотация

BACKGROUND AND OBJECTIVE: Coronary Microvascular Dysfunction (CMD) is characterized by impaired vasodilation and can lead to insufficient blood flow to the myocardium during stress or exertion, affecting millions of people globally. Although invasive wire-based diagnostics such as the index of microcirculatory resistance (IMR) and coronary flow reserve (CFR) provide valuable insights, their adoption in clinical settings remains limited due to procedural complexity and inconsistency. Coronary angiography, one of the most commonly used imaging modalities, offers valuable flow information that assists in diagnosing CMD. However, this information is not fully understood or utilized in current clinical practice.

METHODS: In this study, a 3D-0D coupled multi-physics computational fluid dynamics (CFD) model was developed and calibrated to simulate and study the process of contrast injection and washout during clinical angiography. A contrast intensity profile (CIP) was introduced to describe the dynamics of coronary angiography data. Additionally, sensitivity studies were conducted to evaluate the influence of various coronary lumped parameter model (LPM) parameters on the shapes of CIPs.

RESULTS: The multi-physics model can be effectively calibrated to produce physiologically meaningful hemodynamic results. Sensitivity studies reveal that resistance has a greater impact on the rising and falling slopes of CIP than capacitance, with higher resistance amplifying this effect.

CONCLUSION: This study presents a promising modeling framework for interpreting angiographic data and ultimately extracting information concerning coronary microcirculation. While promising, the approach has not yet been validated in vivo, highlighting the need for future clinical studies.